No
Item
P21
Intermittent suction non-op-
eration time for pedal con-
trol suction 1
P22
Pedal control suction 2
P23
Front suction operating
time for pedal control suc-
tion 2
P24
Rear suction operating
time for pedal control suc-
tion 2
P25
Intermittent suction oper-
ating time for pedal control
suction 2
P26
Intermittent suction non-op-
eration time for pedal con-
trol suction 2
P27
Manual thread trimming
time
P28
Manual thread trimming
suction
P29
Manual suction 1
Operating time
P30
Manual suction 2
Operating time
Description
In the case "5" is selected for "P17", the suction 1 is
held in the stopped state for the period of time set for
this function setting number "P21" when the sewing
machine carries out sewing. The suction 1 carries out
operation and non-operation of suction alternately in
repetition.
In the case this function setting number is set to "0", the
sewing machine will carry out the same operation as it
carries out when the function setting number "P17" is
set to "4: Long suction" regardless of the set value of
the function setting number "P20".
Unit [ms]
This function setting number is used for selecting the
operation of the device connected to the suction 2.
0: OFF
1: Front suction;
2: Rear suction;
3: Front and rear suction;
4: Long suction;
5: Intermittent suction (controlled by time);
6: Intermittent suction (controlled by the number of
stitches)
In the case "2: The needle stop position is not specified"
is selected for the function setting number "P02 Stop
position selection", "6: Intermittent suction (controlled by
the number of stitches" cannot be selected for this func-
tion setting number P22."
In the case "1" or "3" is selected for "P22", the suction
2 is kept in the operating state for the period of time set
for this function setting number "P23" when the front
part of the pedal is depressed to start sewing. Unit [ms]
In the case "2" or "3" is selected for "P22", the suction
2 is kept in the operating state for the period of time set
for this function setting number "P24" when the back
part of the pedal is strongly depressed. Unit [ms]
In the case "5" is selected for "P22", the suction 2 is
kept in the operating state for the period of time set for
this function setting number "P25" when the sewing
machine carries out sewing. The suction 2 carries out
operation and non-operation of suction alternately in
repetition. Unit [ms]
In the case "5" is selected for "P22", the suction 2 is
held in the stopped state for the period of time set for
this function setting number "P26" when the sewing
machine carries out sewing. The suction 2 carries out
operation and non-operation of suction alternately in
repetition.
In the case this function setting number is set to "0", the
sewing machine will carry out the same operation as it
carries out when the function setting number "P22" is
set to "4: Long suction" regardless of the set value of
the function setting number "P25".
Unit [ms]
In the case the manual switch is connected to the sew-
ing machine, this function setting number is used for
setting the time to carry out thread trimming when the
manual switch is pressed. Unit [ms]"
"In the case the manual switch is connected to the
sewing machine, this function setting number is used
for selecting the operation of the device connected to
the suction 1 and suction 2 when the manual switch is
pressed.
0: OFF;
1: Manual suction 1 ON;
2: Manual suction 2 ON;
3: Manual suction 1 and manual suction 2 ON"
In the case the manual switch is connected to the sew-
ing machine and "1" or "3" is selected for "P28", the
suction 1 is kept in the operating state for the period of
time set for this function setting number "P29" when the
manual switch is pressed. Unit [ms]"
In the case the manual switch is connected to the
sewing machine and "2" or "3" is selected for "28", the
suction 2 is kept in the operating state for the period of
time set for this function setting number "P30" when the
manual switch is pressed.
Unit [ms]"
– 29 –
Range
Initial value
0-9000
200
0-6
1
0-5000
300
0-5000
300
0-9000
200
0-9000
200
0-990
40
0-3
3
0-5000
300
0-5000
300