Summary of Contents for 3M 980

  • Page 1 980/980E Ionized Air Gun Instruction Manual...
  • Page 2: Table Of Contents

    Index Section Page 1. General Description ..................3 2. Performance ..................... 3 3. Power Requirements ..................3 4. Air Supply Requirements................. 3 5. Installation ......................4 6. Assembling the Components ................5 7. Operation ......................6 8. Maintenance..................... 7 9. Specifications....................11...
  • Page 3: General Description

    An requires very little maintenance. AC 120 V transformer is supplied with the model 980, and AC 230 V unit is Compact and lightweight, the console supplied with the 980E Ionized Air for the 980 can be mounted anywhere Gun.
  • Page 4: Installation

    (as defined in this Lay the cable inside the groove inside section) may result in damage to the the console. Mount the console using 3M™ 980 Ionized Air Gun that will not the instructions below. be covered by warranty. 5.2 Permanent Mounting 5.0 Installation...
  • Page 5: Assembling The Components

    6.0 Assembling the interconnect. In both cases, use a prefilter as defined in 4.0. Components CAUTION! Protect the hose from sharp objects, abrasion, and high temperatures. Do not pull or pinch the hose while assembling the components. 6.1 Insert the larger end of the filter cartridge into the fitting at the end of the flexible air hose.
  • Page 6: Operation

    Insert the wall room temperature as well as heat from transformer into a properly surrounding equipment. grounded AC 120V (for 3M 980 Ionized Air Gun) or AC 230V (for 7.4 Verify that neither the gun trigger 3M 980E Ionized Air Gun) nor the foot pedal is depressed.
  • Page 7: Maintenance

    8.0 Maintenance 8.22 Remove the hose and filter from The 3M™ 980/980E Ionized Air Gun the console by pulling the requires very little maintenance. textured rubber plug where the Occasional cleaning of the case and hose emerges from the console.
  • Page 8 8.4 Replacement & Optional Parts 8.35 Align the blunt prongs of the Table 1 lists the replacement parts and emitters with the holes in the optional parts available for the 3M™ barrel and set the clip into place. 980/980E Ionized Air Gun. Part...
  • Page 9 6 inches (15 cm) 713 Handheld Ionizer Tester. and balance should be within +/- 30 volts of zero. 9.0 Specifications for 3M™ 980/980E Ionized Air Gun 9.1 General Audible Noise 73dBA @ 1 meter, 30 psi (2 bars) pressure to air gun Conducted EMI 29 dBµ, average level, from 100 kHz-1.1MHZ...
  • Page 10 3M Electronic Handling & Protection Division Customer Service Dept.: (800) 328-1368 Technical Support Helpline: (512) 984-3200 Outside of the United States: For customer service and technical support, please contact your local representative of the 3M Electronic Handling & Protection Division.
  • Page 11: Specifications

    3M product. Except where prohibited by Warranty; Limited Remedy; Limited law, 3M will not be liable for any loss or Liability. damage arising from this 3M product, This product will be free from defects in...