  • Page 1 Ionized Air Gun 980/980E ™ User’s Guide...
  • Page 2: Table Of Contents

    Index Section Page 1. General Description ..................3 2. Performance ....................3 3. Power Requirements ..................3 4. Air Supply Requirements ................4 5. Installation ....................4 6. Assembling the Components ................ 6 7. Operation ...................... 7 8. Maintenance ....................8 9.
  • Page 3: General Description

    The console, gun, and air hose are all static-dissipative and ESD-safe. 2.0 Performance The Ionized Air Gun 980 reduces a static charge of +/- 1000 V to +/- 100 V in less than 1 second at a distance of 6 inches (15 cm) and 30 psi (2 bars) inlet pressure when tested in accordance with the ESD Association ionization standard ANSI/ESD-S3.1, and IEC standard 61340-5-1, Figure A.5.14 Balance...
  • Page 4: Air Supply Requirements

    Please note that the failure to use clean, dry air or nitrogen (as defined in this section) may result in damage to the Ionized Air Gun 980 that will not be covered by warranty.
  • Page 5 When mounting to a hollow wall, be sure to use adequate screws and wall anchors to ensure stability of installation. 5.3 Non-permanent Mounting Use 3M Dual Lock Fastener Strips or pads to attach the console to a flat ™...
  • Page 6: Assembling The Components

    6.0 Assembling the Components CAUTION Protect the hose from sharp objects, abrasion, and high temperatures. Do not pull or pinch the hose while assembling the components. 6.1 Insert the larger end of the filter cartridge into the fitting at the end of the flexible air hose. Push the filter gently until it is firmly seated and the metal Filter Release Tab pops out, locking the filter into place.
  • Page 7: Operation

    7.0 Operation WARNING The 3M Ionized Air Gun 980/980E is NOT for use in hazardous environments where the possiblity of ™ explosion exists. 7.1 Make sure the Power Switch on the top of the console is in the OFF position. Insert the power cord to the transformer into a properly grounded AC 120V (for 3M Ionized Air Gun 980) or AC 230V (for 3M Ionized Air Gun 980E) receptacle.
  • Page 8: Maintenance

    8.2 Replacing the Air Filter 3M recommends changing the filter every three months or when it begins to look dirty. Replacement filters are available from 3M; see Table 1. 8.21 Hold down the filter release button on the side of the console.
  • Page 9 A replacement tip containing a pair of emitter points is available from 3M; see Table 1. 8.31 Insert the tip of a screwdriver into the slot on the gun barrel. See Figure 4.
  • Page 10: Specifications

    8.4 Replacement & Optional Parts Table 1 lists the replacement parts and optional parts available for the 3M ™ Ionized Air Gun 980/980E. 8.5 Testing for Proper Operation 8.51 To make sure that your ionizing air gun is working properly, check the balance and discharge levels.
  • Page 11 3M Electronic Solutions Division Customer Service Dept.: (866) 722-3736 Technical Support Helpline: (512) 984-6703 Outside of the United States: For customer service and technical support, please contact your local representative of the 3M Electronic Solutions Division.
  • Page 12 Limit of Liability - In no event will 3M or Seller be responsible or liable for special, incidental, or consequential losses or damages, whether based in tort or contract.
  • Page 13 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: 980E-X...