Outdoor Unit Installation
Installation Instructions –
Outdoor Unit
Step 1: Selecting an installation location
choose an appropriate location. Use the following
guidelines to help you select an appropriate
location.
P
following guidelines:
Meets all spatial requirements shown in
Good air circulation and ventilation
the unit and will not cause vibration
Noise from the unit will not disturb others
Protected from prolonged periods of
exposure to direct sunlight or rain
Page 19
Indoor Unit Installation
Minimum clearance
on the left side
of unit: 12 in (30cm)
DO NOT
)
mrcool.com
Minimum Clearance
above unit:
24in (60cm)
24 in (60cm)
above
12in (30cm)
on left
install unit in the following locations:
Near an obstacle that will block air inlets and
outlets
Near a public street, crowded areas, or where
noise from the unit will disturb others
Near animals or plants that will be harmed
by hot air discharge
Near any source of combustible gas
In a location that is exposed to large amounts
of dust
In a location exposed to a excessive
amounts of salty air
In a location that exposes the unit to large
amounts of forced water
5
Minimum Clearance
24in (60cm)
on the right side
on right
of the unit: 24 in (60cm)
Fig. 5.1