Control Locations; Specifications; Operating Data Chart - Traulsen TE Series Service Manual

Refrigerated equipment stand models
Hide thumbs Also See for TE Series:
Table of Contents

Advertisement

II. j - CONTROL LOCATION:
On all TE-Series refrigerator models, the micro-
processor control is located on the louver assembly.
The louvers/refrigeration system are mounted standard
on the left side, but as an option are available mounted
on the right (see figure 2).
Fig. 2
Control Location
II. k - OPERATING DATA CHART:
Refrigerated Models (cabinet temperature set at 38°F)
Ambient
Suction Pressure
Suction Temperature
Discharge Pressure
Discharge Temperature
II. GENERAL INFORMATION (cont'd)
°
°
70
F
100
F
35 PSIG
50 PSIG
°
°
3
F
16
F
200 PSIG
295 PSIG
°
°
88
F
115
F
II. l - SPECIFICATIONS:
TE-Series Refrigerated Equipment Stands
Horsepower
Condensing Unit - BTU/HR
Condensing Unit Amp Draw
Fan, Lights, Etc. Amp Draw
Refrigerant
Refrigerant Charge (oz.)
TE-Series Refrigerated Equipment Stands
Horsepower
Condensing Unit - BTU/HR
Condensing Unit Amp Draw
Fan, Lights, Etc. Amp Draw
Refrigerant
Refrigerant Charge (oz.)
TE-Series Refrigerated Equipment Stands
Horsepower
Condensing Unit - BTU/HR
Condensing Unit Amp Draw
Fan, Lights, Etc. Amp Draw
Refrigerant
Refrigerant Charge (oz.)
TE-Series Refrigerated Equipment Stands
Horsepower
Condensing Unit - BTU/HR
Condensing Unit Amp Draw
Fan, Lights, Etc. Amp Draw
Refrigerant
Refrigerant Charge (oz.)
-3-
TE036
TE048
TE060
1/3 HP
1/3 HP
1/3 HP
2440
2440
2440
4.5
4.5
4.9
0.6
0.6
1.1
R-404A
R-404A
R-404A
14.0
14.5
16.0
TE065
TE072
TE084
1/3 HP
1/3 HP
1/3 HP
2440
2440
2440
4.9
4.9
4.9
1.1
1.1
1.1
R-404A
R-404A
R-404A
16.5
16.5
17.0
TE096
TE110
TE125
1/2 HP
1/2 HP
1/2 HP
4090
4090
4090
9.6
9.6
9.6
1.5
1.5
1.5
R-404A
R-404A
R-404A
20.0
20.0
20.0
TE139
1/2 HP
4090
9.6
1.9
R-404A
21.0

Advertisement

Table of Contents
loading

Table of Contents