IVEN B60 TFS 24 IVEN B60 TN 24 INSTALLATION USE AND MAINTENANCE 00334052 - 1 edition - 03/2011...
Page 2
Damage and/or injury caused by incorrect installation or use and/or damage and/or injury due to non-observance of the manufacturer’s instructions shall relieve UNICAL from any and all contractual and extracontractual liability. Before installing the boiler, check that the technical data corresponds to requirements for its correct use in the system.
General info TECHNICAL FEATURES AND DIMENSIONS ............pag. Technical features ..............pag. Dimensions ................pag. Hydraulic circuits ..............pag. Operating data ................. pag. General features ..............pag. DIRECTIONS FOR INSTALLERS ................. pag. Installations rules ..............pag. Installation ................pag. 2.2.1 Packing ...............
Keep the packaging out of the reach of chil- dren as it represents a choking and suffoca- tion hazard. UNICAL waives all liability for injury to per- sons and animals or damage to property resulting from non-observance of the abo-...
Installation info 2.2.4 - VENTILATION Boiler model IVEN B60 TN 24 have an open Boiler model IVEN B60 TFS 24 have a sea- combustion chamber and have been desi- led combustion chamber with reference to the environment in which it is installed, so no...
Page 10
This duct may be obstructed or may be unsuitable for the discharge of flue gas into the atmosphere. UNICAL waives all liability for damage cau- sed as a result of incorrect installation, use, modification of the boilers or for non-ob-...
Installation info 2.2.6 - POSITIONING OF TERMI either take place through the roof or directly FORCED DRAUGHT BOILER outwards the room they are installed in. The NALS FOR TYPE ‘’C’’ The distances specified in appliance standar- following distances shall be considered for ds and laws must be complied with when po- BOILERS terminals proper positioning:...
Page 12
Installation info 2.2.7 - SMOKE DISCARGE AND type AIR SUCTION DUCT CONFIGURATION C12, C32, C42, C52, C62, C82 - B22 Boiler designed for connection to hori- zontal exhaust and suction terminals directly into the atmosphere using coaxial or dual ducts. The distan- ce between the air intake duct and the type flue gas outlet duct must be at least...
Page 13
Installation info 2.2.8 Discharge of flue gas into EXAMPLE WITH COAXIAL PIPES coaxial ducts with a diameter of 100/60 mm (Type A acces- sories) To 1,5 m Type C12 The minimum lenght of horizontal coaxial ducts is 0.5 metres. The maximum allowa- ble length of horizontal coaxial ducts is 3 metres;...
Page 14
Installation info 2.2.9 Flue gas exhaust and air EXAMPLE WITH DUAL DUCT suction with dual ducts with 80 mm diameter (type B acces- sories) N.B. The maximum allowable load loss must be the same as the values shown in the following examples, depending on the type of installation.
Page 15
Installation info Example No. 1 Primary air suction from perimeter wall and flue gas discharge on roof. Maximum allowable load loss: 65 Pa fig. 15...
Installation info Example No. 2 Primary air suction from perimeter wall and flue gas discharge from the same outside pe- rimeter wall. Maximum allowable load loss: 80 Pa CALCULATION OF PRESSURE LOSSES FOR DISCHARGE AND SUCTION DUCTS 200 mm Bear in mind the following parameters when Hmin.
PRODUCTION OF D.H.W. UNICAL shall not be held responsible for da- mage caused by non-observance of this tech- nical precaution. UNICAL shall not be held responsible for damage caused by non-observance of this technical precaution.
Installation info 2.3 - WIRING DIAGRAM IVEN B60 TN/TFS 24 GREEN GREEN WHITE BROWN WHITE WHITE WHITE GREEN BLUE BROWN GREEN GREEN BLUE BLUE WHITE BROWN BLUE BROWN WHITE WHITE BROWN BLACK BROWN BLUE BROWN BLUE BLACK ORANGE GREY BLUE BLACK WHITE = Heating detector...
Page 19
Installation info WIRING DIAGRAM - IGNITION CARD IVEN B60 TN/TFS 24 CONNECTION IVEN B60 TN 24 IVEN B60 TFS 24 BLEU BLEU BLEU BLEU BLACK BLACK BLEU BLEU ORANGE ORANGE BROWN BROWN BLACK GREEN BLACK WHITE BLACK BROWN BROWN BROWN BLEU ALIMENTAT.
Installation info TABLE OF RESISTANCE VALUES AS A FUNCTION OF THE TEMPERATURE OF THE HEATING SENSOR (SR) AND D.H.W. SENSOR (SS) T°C 32755 31137 29607 28161 26795 25502 24278 23121 22025 20987 20003 19072 18189 17351 16557 15803 15088 14410 13765 13153 12571...
Regulation info (pressure at the hydrometer 0.8/1 bar); 3.4.2 - SWITCHING ON/OFF 2.5 - STARTING THE any cut-off taps of the system are open; BOILER the mains gas corresponds to that with To switch on and off the boiler follow the indi- which the boiler has been calibrated: othe- cations in the “Users’...
Page 22
Any subsequent conversion must be perfor- med by qualified technicians who will use the kits supplied by Unical and perform the con- version and required adjustments for correct preparation of the boiler for use. To convert the boiler from one type of gas to another: remove the main burner;...
Regulation info 2.8 - ADAPTING THERMAL POWER TO THE HEA- TING SYSTEM With the heating system cold. Connect the pressure gauge to the burner as shown in fig. 28, switch on the boiler in he- ating mode and proceed as follows. Wait about two minutes to allow the pres- sure to reach the operating value.
Service info USERS' INSTRUCTION 3.1 - CONTROL PANEL fig. 30 Summer / Off / Winter / Anti-freeze Hot water temperature control Thermometer selector Cut-off light Power light Release button Heating water temperature control Pressure gauge Summer – Off – Winter – Boiler antifree- rature range is 35-85°C.
UNICAL declines all responsibility for injury IMPORTANT to persons and animals and damage to pro- When the boiler anti-frost protection function perty resulting from tampering or impro- is active, both the central heating and D.H.W.
Page 26
DATA BADGE CE Marking - The essential requirements of the Directive regarding electromagnetic compatibility - The CE marking documents that the boilers satisfy: 2004/108/CEE (Directive - The essential requirements of the Directive regarding gas appliances (Directive - The essential requirements of the Efficiency Directive (Directive 92/42/CEE) 2009/142/CEE) 2006/95/CEE - The essential requirements of the low voltage Directive (Directive...
Page 28
46033 casteldario - mantova - italia - tel. 0376/57001 (r.a.) - telefax 0376/660556 La Unical declina ogni responsabilità per le possibili inesattezze se dovute ad errori di trascrizione o di stampa. Si riserva altresì il diritto di apportare ai propri prodotti quelle modifiche che riterrà necessarie o utili, senza pregiudicarne le caratteristiche essenziali.