Drive Selection - Fagor DDS Series Hardware Manual

Table of Contents

Advertisement

Verify that the motor chosen in previous selections meets the following
condition:
Peak torque equal to or greater than the calculated max. torque:
Rated torque equal to or greater than the calculated RMS value:
Summary of the three pre-selections
 Maximum speed equal to or greater than calculated value in RPM
 Stall torque equal to or greater than calculate continuous value
M
CONTINUOUS
 Motor inertia equal to or greater than inertia J
 Peak torque equal to or greater than calculated value M
 Rated torque equal to or greater than calculated RMS value M

Drive selection

Once the motor has been selected, check the electrical characteristics table
in the FXM/FKM AC servomotors manual.
There are several drives available for each motor and the peak torque
obtained with each one of them will be different.
Select the drive that can provide a motor peak torque greater than the
maximum torque required in the application and whose rated current is
equal to or greater than the rated current of the motor.
M PEAK
M MAX
M RATED
M RMS
/ K
LOAD
  Selection criteria
5.
MOTOR
MAX
RMS
HARDWARE
DDS
Ref.1912
· 205 ·

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents