Connection Between Cncelite And Bcsd-Ec Axis Drive - Fagor BCSD Installation Manual

Ethercat
Hide thumbs Also See for BCSD:
Table of Contents

Advertisement

Installation manual
3.1.

Connection between CNCelite and BCSD-EC Axis Drive

Cable name: BSC-EC-
Cable between CNCelite communications board EtherCAT AXES · B64 connector · and
BCSD-EC axis drive · CN3 connector · .
Length  : 05/10/15 m.
Pinout
2x RJ-45 connectors.
Characteristics
Type: Shielded. Twisted pairs (1 x 2 x 0.22 mm
Flexibility: Superflexible.
Minimum static bending radius of 50 mm and a dynamic radius of 95 mm.
Cover: PUR.
Impedance: Cat. 5. 100/120 .
20|52 - BCSD EtherCAT
C N C e l i t e · B 6 4 ·
P i n
T D +
1
T D -
2
3
R D +
4
5
R D -
6
7
8
S H I E L D
H O U S I N G
PIN
SIGNAL
DESCRIPTION
1
TD +
Transmission Data +
2
TD -
Transmission Data -
3
RD +
Receiver Data +
4
-
5
-
6
RD -
Receiver Data -
7
-
8
-
Housing Shield
Screening
Beta series EtherCAT Servo Drives | Ref.2107
B C S D - E C · C N 3 ·
P i n
1
T D +
2
T D -
3
R D +
4
5
6
R D -
7
8
H O U S I N G
S H I E L D
SIGNAL
PIN
TD +
1
TD -
2
RD +
3
-
-
4
-
-
5
RD -
6
-
-
7
-
-
8
Shield Housing
2
).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents