Error Reset - Fagor DDS Series Hardware Manual

Table of Contents

Advertisement

  Power supplies
Other connectors
2.
94
DDS
HARDWARE
Ref.1912
· 64 ·
X1 connector
The communication between all the modules that make up the DDS system
is established through connector X1.
X1
F. H2/23
Connection of the internal bus between modules through connector X1.
A ribbon cable is provided with each module (power supply or drive) for this
connection.
X2 connector
The power supply module may be controlled through X2.
XPS-25|65
X2 CONNECTOR
1
7
Phoenix 5.00 mm
F. H2/24
Control of the power supply module through connector X2.
The internal circuits are protected with a 1.25 A fuse.
MANDATORY. Remember that the internal circuits of PS-65A non-
regenerative power supplies must be powered by an external 24 V DC
power supply, ·APS-24·; that's why its control connector has three terminals
more than connector X2 of the XPS.
The following table shows the values for gap, tightening torque, sections and
other data of the plug-in connector for X2.
T. H2/19 Plug-in connector for X2. Technical data.
Connector data
Nr of poles
Gap (mm)
Min./max. tightening torque (N·m)
Screw thread
Min./max. section (mm²)
Rated current In (A)
Wire data
1x
Length to strip (mm)
1

ERROR RESET

2
NOT CONNECTED
3
GND
4
NOT CONNECTED
5
SYSTEM SPEED
ENABLE
6
7
SYSTEM OK
XPS-25
7
5.00
0.5/0.6
M3
0.2/2.5
12
7
XPS-65
7
5.00
0.5/0.6
M3
0.2/2.5
12
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents