FAGOR supplies the aerial connector in the accessory bag. The values for
pitch, tightening torque, pole section (input holes of the connector) and other
data regarding the terminals of this connectors are shown in the following
table.
T. H4/14 Aerial connector that may be plugged into X54. Technical data
Connector data
Nr of poles
Gap (mm)
Min./max. tightening torque (N·m)
Screw thread
Min./max. section (mm²)
Rated current In (A)
Wire data
x1
Length to strip (mm)
T. H4/15 Signals at the pins of connector X54.
1
RESET
2
GND
3
DRIVE OK
4
DRIVE OK
5
0 V DC
6
24 V DC
When the control circuit is supplied with 24 V DC (pins 5 and 6) the module
runs an internal test. If it runs OK, it closes the module status DRIVE OK
contact (pins 3 and 4).
This contact stays closed while the supplied 24 V DC are maintained and
internally the module runs properly.
A 1.25 A (F) fuse protects the internal circuits.
The consumption of these control signals is between 4.5 and 7 mA.
X56 connector. External Ballast
Screw-in type 6-pin plug-in connector used to connect the external braking
resistor(s). Located at the bottom of the module and identified as X56. See
figure.
F. H4/14
X56 connector. External Ballast.
6
5
0.5/0.6
M3
0.2/2.5
12
7
System error RESET input. (24 V DC; 4.5÷7 mA)
Ground
Contact indicating module status.
It opens in case of failure.
Limit 1 A at 24 V.
0 V reference input
Voltage input (24 V DC; 4.5÷7 mA).