PROBLEM
Airflow alarm condition
Maintenance 7-18
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
POSSIBLE CAUSES
Fan speed tolerance
·
limit exceeded
1261B User Manual
WHAT TO DO
·
Check fan TACH outputs at rear
panel
Query EMS to check fan speed
·
values and to verify limits. Refer
to Chapter 4.
Check for restrictions to airflow at
·
mainframe intake and exhaust.
Clean mainframe module cooling
·
fan filter.