Settings; Operating Modes; Tensioning Force / Welding Time - Titan TA750 Instruction Manual

Battery powered strapping tool for plastic strap
Table of Contents

Advertisement

Available languages

Available languages

8.

Settings

(press push-button 1 for a moment / LED signal lamp must be bright)

8.1. Operating modes

The TA750 can be operated in three different operating modes:
Automatic
Semi-automatic  SEM
Manual
a.) Press and hold the SET
button for 3 seconds to choose
one of the operating modes.
The operating mode which is set
starts flashing.

8.2. Tensioning force / welding time

Press and hold the adjust button for 3 seconds to adjust
the tensioning force or welding time until the number above
the adjust button flashes.
Now you can adjust the desired tensioning force / welding
time by pushing the adjust button repeatedly until the
desired value is displayed.
1 = low tensioning force / welding time
9 = high tensioning force / welding time
When you release the adjust button the set value will stop
blinking after about three seconds and the value you set will be
stored.
TA750
(0001)
The setting only works when being enabled!
 AUT
 MAN
H TA750 EU 46/17
b.) Afterwards press the SET button as
long as the desired operation mode starts
flashing.
When you release the SET button, the
operation mode you set will stop blinking
after about 3 seconds, the set operation mode
is stored.
Welding time
Tensioning
force
46 / 98

Advertisement

Chapters

Table of Contents
loading

Table of Contents