Zennio MAXinBOX FANCOIL 2CH2P Quick Start Manual

Zennio MAXinBOX FANCOIL 2CH2P Quick Start Manual

Fan coil controller for 2-pipe fan coil units – 2 channels

Advertisement

Quick Links

Fan coil controller for 2-pipe fan coil units – 2 channels
ZCL-2XFC2P
FEATURES
 Up to two blocks to control 2-pipe fan coil units.
 Manual output operation with push button and LED status
indicator.
 Logical functions included.
 Output timing facilities.
 Total data saving on power failure.
 Size 90 x 67 x 79 mm (4.5 DIN units).
DIN rail mounting (EN 50022), through pressure.
 No external power supply required other than the bus.
 Integrated KNX BCU.
 Possibility to connect different phases.
 Conformity with the CE directives (CE-mark on the right side).
1. Fan control outputs
5.Programming/Test button
Programming/test button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe
mode. If this button is held for more than 3 seconds, the device enters the test mode.
Programming/Test LED: programming mode indicator (red). When the device enters into safe mode, it blinks (red) every half second. The manual
mode is indicated by the green color. During the start-up (reset or after KNX bus failure) and if the device is not in safe mode, it starts a blue blinking
sequence.
GENERAL SYSTEM SPECIFICATIONS
CONCEPT
Type of device
Voltage (typical)
Voltage range
KNX
Maximum
supply
consumption
Bus connection
External power supply
Operation temperature
Storage temperature
Operation humidity
Storage humidity
Complementary characteristics
Protection class
Operation type
Device action type
Electrical stress period
Degree of protection
Installation
KNX bus failure response
Response when restarting KNX bus
Operation indication
Weight
PCB CTI index
Enclosure
(1)
Maximum consumption in the worst case scenario (KNX Fan-In model)
© Zennio Avance y Tecnología S.L.
2. Valve outputs
6.Output control button
DESCRIPTION
Electric operation control device
29VDC SELV
21...31V DC
Voltage
29VDC (typical)
(1)
24VDC
Typical bus connector TP1 for rigid cable 0.80mm Ø
No
from 0ºC to +55ºC
from -20ºC to +70ºC
5 to 95% RH (no condensation)
5 to 95% RH (no condensation)
Class B
II
Continuous operation
Type 1
Long
IP20, clean environment
Independent device to be mounted inside electrical panels with DIN rail (EN 50022)
Data saving and output status change according to parameterization.
Data recovering and output status change according to parameterization.
Programming LED indicates programming mode (red) and test mode (green).
Output status LED indicators reflect current output state.
235g
175V
PC FR V0 halogen free
Edition 2
MAXinBOX FANCOIL 2CH2P
7
6
3
Figure 1. MAXinBOX FANCOIL 2CH2P
3.Programming/Test LED
7.Output status LED indicator
mA
5.8
10
Further information
www.zennio.com
Technical Documentation
1
5
4
2
4.KNX connector
mW
168.2
240
Page 1 / 2

Advertisement

loading

Summary of Contents for Zennio MAXinBOX FANCOIL 2CH2P

  • Page 1  No external power supply required other than the bus.  Integrated KNX BCU.  Possibility to connect different phases.  Conformity with the CE directives (CE-mark on the right side). Figure 1. MAXinBOX FANCOIL 2CH2P 1. Fan control outputs 2. Valve outputs 3.Programming/Test LED 4.KNX connector...
  • Page 2 KNX bus before energizing the power circuit. Figure 2. 2-pipe fan coil wiring example with 3-speed fan. Attaching MAXinBOX FANCOIL 2CH2P to DIN rail: Removing MAXinBOX FANCOIL 2CH2P from DIN rail: Figure 3. MAXinBOX FANCOIL 2CH2P DIN-rail assembly SAFETY INSTRUCTIONS ...