Fisher & Paykel DW60UC2X Instruction Manual

Fisher & Paykel DW60UC2X Instruction Manual

Hide thumbs Also See for DW60UC2X:

Advertisement

DISHWASHER
DW60UC2X, DW60UC6X, DW60UC6B models
INSTALLATION GUIDE
NZ AU

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DW60UC2X and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fisher & Paykel DW60UC2X

  • Page 1 DISHWASHER DW60UC2X, DW60UC6X, DW60UC6B models INSTALLATION GUIDE NZ AU...
  • Page 2: Safety And Warnings

    SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS WARNING! Ensure all water connections are turned OFF. It is the responsibility of the plumber and Electrical shock hazard electrician to ensure that each installation complies with all Codes and Regulations. Before installing the dishwasher, remove the house fuse or open the The dishwasher MUST be installed to allow for future removal from the enclosure if circuit breaker.
  • Page 3: Parts Supplied

    PARTS SUPPLIED TECHNICAL DATA Technical data Check the electrical data on the rating label (located on the left-hand side of the dishwasher’s stainless steel inner door). Should the data on the rating label be different to those specified below, consider those on the rating label as correct. DW60UC2 models DW60UC6 models Capacity...
  • Page 4: Product Dimensions

    PRODUCT DIMENSIONS PRODUCT DIMENSIONS Overall height of product* 820 - 880 Overall width of product (excl. side seals) NOT TO SCALE Overall depth of product Depth of toe kick 46 - 90 FRONT Height from floor to bottom of door panel 100 - 160 Depth of open door Width of toe kick panel...
  • Page 5: Cabinetry Dimensions

    CABINETRY DIMENSIONS PLAN PROFILE CABINETRY DIMENSIONS Minimum clearances from adjacent cabinetry Inside width of cavity 600 - 610 Inside depth of cavity min. 574 Inside height of cavity* 820 - 880 * depending on adjustment of levelling feet min. 13 mm min.
  • Page 6: Cavity Preparation

    CAVITY PREPARATION IMPORTANT! To prevent possible steam damage to the cabinetry, ensure that any bare wood surrounding the dishwasher is sealed with an oil-based paint or moisture-proof polyurethane. IMPORTANT! Apply moisture protection tape The power outlet must be Apply moisture protection tape to located in a cabinet adjacent to the dishwasher cavity.
  • Page 7 TOE KICK INSTALLATION OPTIONS SEPARATE CUSTOM PANEL CONTINUOUS CUSTOM PANEL Note door overhang and swing range reltive to height and depth of toekick panel. As the panel is continuous, cutting back panel is likely to be necessary to ensure seamless Mark out the bracket location on integration.
  • Page 8 TOE KICK INSTALLATION OPTIONS PRE-FINISHED TOEKICK Distance between bottom of door location and floor (mm) 105 - 100 110 - 105 115 - 110 120 - 115 125 - 120 130 - 125 135 - 130 140 - 135 145 - 140 145+ TOEKICK PROFILE VIEW Measure the distance between the floor and...
  • Page 9  SECURING PRODUCT Centre product As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted. Plastic spacers can be cut to size then taped to the sides of the cut path dishwasher to improve example overall stability.
  • Page 10  PLUMBING AND DRAINAGE OPTIONS Ø 38 MM STANDPIPE DRAIN HOSE JOINER ONTO SINK TRAP/WASTE TEE Installer to provide drain hose joiner to suit min. 15mm waste tee. If space is limited for fixing, push If space is limited for fixing, hose through drain push hose through drain hose hose support...
  • Page 11: Connect To Power

     CONNECT INLET HOSE TO HOT WATER Plumbing — Water inlet connection IMPORTANT! Ensure the appliance is connected to the water main using the supplied new water inlet hose. Do not use old hoses. Do not shorten the inlet hose. Follow the water connection requirements. We recommend a cold water connection for best performance and energy efficiency.
  • Page 12: Troubleshooting

     TROUBLESHOOTING Excessive water remaining above the filter plate, after the rinse cycle (This can be displayed as an fault) Check for a kinked drain hose, blocked waste connection, highloop not properly installed, drain hose not routed correctly or spray arms not in place. No water supply (This is displayed as an fault) Check water is connected and turned on.
  • Page 13: Final Checklist

     FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Check that the door opens and closes freely without resistance to adjacent Check all parts are installed. cabinetry. Ensure that all panels and parts thereof are secure and final electrical tests have been Check that the electrical outlet is accessible and located in an adjacent cupboard.
  • Page 17 FISHERPAYKEL.COM © Fisher & Paykel Appliances 2020. All rights reserved. The models shown in this guide may not be available in all markets and are subject to change at any time. The product specifications in this guide apply to the specific products and models described at the date of issue.

This manual is also suitable for:

Dw60uc6xDw60uc6b

Table of Contents