Multi-application outputs module 10 A
Safety instructions
The installation and mounting of electrical appliances
must only be performed by qualified electricians,
in compliance with installation standards and in
accordance with the guidelines, provisions and safety
and accident prevention regulations in force in the
country concerned. Failure to follow these installation
instructions may damage the device, cause a fire or
give rise to hazards. Risk of electric shock. Switch off
the installation before performing any operation on the
device or the load. Do not forget to include all of the
circuit breakers which supply potentially dangerous
voltages to the device or to the load.
Risk of electric shock. The appliance is not suitable
for providing isolation. Risk of electric shock on
SELV/FELV installations. Not suitable for switching
SELV/FELV voltages. Only connect one motor per
output. Use only motors with mechanical or electronic
limit switch sensors. Check the adjustment of the
limit switches. Follow the motor manufacturer's
instructions. There is a risk of damage to the unit.
Do not connect to three-phase motors. There is
a risk of damage to the unit. Observe the motor
manufacturer's recommendations for the minimum
reverse rotation time and the maximum continuous
operation time. These instructions for use form an
integral part of the product and must be retained by
the end user.
Product description
Diagram 1
1 KNX bus connection terminal.
2 Connections of loads.
3 Illuminated programming button.
4 Operation button for manual operation for one
output with status LED.
1
z
Function
System information
This device is a product of KNX system and
corresponds to the KNX guidelines. Detailed
specialised knowledge obtained from KNX training
courses is required for understanding.
The planning, installation and commissioning of
the device is carried out with the help of KNX-
certified software.
Systemlink commissioning
The function of the device is software-dependent.
The software is to be taken from the product
database. You can find the latest version of the
product database, technical descriptions as well
as conversion and additional support programmes
on our website.
Functional description
The device receives telegrams from sensors or
other controllers via the KNX installation bus and
switches electrical loads with its independent relay
contacts.
Correct use
- Switch electrical loads of 230 V~ with potential-
free contacts.
- Switching electrically operated motors of
230 V~ for blinds, shutters, awnings and similar
hangings.
- Mounting on DIN rail according to DIN EN 60715
in the distribution box.
- Control of 24 V s electric motors for Venetian
blinds, roller shutters and awnings, or any other
24 V s motor controlling an opening.
- Control of 230 V~ motors for fan-coil units.
Product characteristics
- Manual activation of the outputs on the device
possible, building site operation.
- Status display of the outputs on the device
- Scene function.
- Forced position by higher-level controller.
- Connection of various external conductors
possible.
Functions in switch operation:
- Time switching functions.
Functions in roller shutter/blind operation:
- Position can be started directly.
- Slat position directly controllable.
- Feedback of operating state, shutter position and
slat adjustment.
Available functions:
- Lighting
- Heating
- Shutters and blinds 230 V~
- Shutters and blinds 24 V s
- 2-tube fan-coil units
- 4-tube fan-coil units
H
Systemlink commissioning:
Depending on the programming, the manual
operation is activated permanently or for a time
period configured via the application software. If
the manual operation is blocked via the application
software, no activation takes place.
Operating outputs in manual operation
Operation takes place per output by briefly
pressing the operation button repeatedly (table1).
Risk of destruction due to simultaneous
pressing of the buttons for UP and DOWN
if a motor is connected when the motor is
in unprogrammed state!
Motors, hangings and the device may
be destroyed!
Always only press one button in manual
operation for unprogrammed devices.
Status.
Behaviour when
button pressed briefly.
Switching operation
Load is switched
Switch ON the connected
off. Status LED
load. Status LED of button 4
of the button 4
lights up.
is off.
Load is switched
Switch OFF the connected
on, status LED
load. LED goes out.
of the button 4
lights up.
Roller shutter / blind operation
Output is in
Movement operation starts.
standby, status
Status LED of the button 4
LED of the
lights up.
button 4 is off
H
If the roller shutter/blind is
in final position, the button
opposite must be pressed to
move the shutter / blind
Output active,
Movement operation stops,
status LED of the
LED goes out.
button 4 lights
up.
Table 1: Manual operation
Installing the appliance
Electric shock in the event of contact with
live parts!
Electric shock can cause death!
Before working on the unit, switch off the
installation and cover the neighbouring
conductive parts!
A critical temperature increase may occur
if too large a load is connected to the
device!
The device and connecting cables may be
damaged at the terminal connection!
Do not exceed the maximum permissible
load per device!
Risk of damage in the event of parallel
installation of multiple motors on a single
output!
The limit switches risk being damaged!
The motors, opening elements and the
device may be destroyed!
Connect only one motor per output!
H
Observe temperature range. Provide sufficient
cooling.
• Mount device onto DIN rail in accordance with
DIN EN 60715
Connect device
Diagram 2
M
M
L
230 V~
N
+
24 V
s
-
6LE001366B

Advertisement

loading

Summary of Contents for hager TYF61 Series

  • Page 1 Function Status. Behaviour when button pressed briefly. System information Switching operation This device is a product of KNX system and corresponds to the KNX guidelines. Detailed Load is switched Switch ON the connected specialised knowledge obtained from KNX training off. Status LED load.