Download Print this page

Bradford White E32-120R User Manual page 8

Conversion kit instructions
Hide thumbs Also See for E32-120R:

Advertisement

Instructions for Conversion of Commercial Electric Models
Phase Conversion Only kits
Volts
208
240
480
Volts
208
240
480
Recheck and inspect to make certain all components involved in the
conversion are correct and secure.
Recheck all of the electrical wiring changes made against the wiring diagram requirements for accuracy.
Check to insure all of the electrical connections are tightly secured and the electrical wire routings are
orderly.
Special attention should be given to the electrical heating elements. The wattage and voltage rating of the
element is marked on the element itself.
Additionally, the element wattage can be verified by checking the electrical resistance (ohms of resistance)
with an Ohm Meter. This should be done initially before connecting the element to the circuit. The element
resistance should be plus or minus 5 percent of the following values:
Element
Wattage
2000
3000
4000
4500
5000
6000
Table 2. Phase Conversion Kits.
6KW
Conversion
Volts
Kit
265-45246-13
208
265-45246-07
240
265-45246-01
480
13.5KW
Conversion
Volts
Kit
265-45246-16
208
265-45246-10
240
265-45246-04
480
Confirm the marking agrees with the intended conversion.
Table 3. Ohms of Electrical Resistance.
Voltage Rating of the Element
208 volts
21.6
14.4
10.8
9.6
8.7
7.2
9KW
Conversion
Volts
Kit
265-45246-14
208
265-45246-08
240
265-45246-02
480
15KW
Conversion
Volts
Kit
265-45246-17
208
265-45246-11
240
265-45246-05
480
WARNING
240 volts
28.8
19.2
14.4
12.8
11.5
9.6
8
12KW
Conversion
Kit
265-45246-15
265-45246-09
265-45246-03
18KW
Conversion
Kit
265-45246-18
265-45246-12
265-45246-06
480 volts
115.2
76.8
57.6
51.2
46.1
38.4

Advertisement

loading

This manual is also suitable for:

E32-50sE32-80r