3.3.6 KeepAlive

Keep-Alive is a mechanism for detecting dead connections in TCP connections. When users does not send any data,
TCP link will periodically send "Keep-Alive" information to maintain the idle link, avoiding dead connections
consuming unnecessary system resources. This setting is valid under TCP. Users can customize the Keep-Alive switch
and other parameters.
Keepalive parameters:
Time: Start probe message after how many seconds the TCP link has no data message transmitted ;
Intv: Time interval between the previous probe message and the next probe message;
Probes: Maximum number of probe failures. When the number of sniffing failures reaches this number, TCP
connection will be disconnected.

3.3.7 Timeout restart

Timeout restart (no data restart) function is mainly used to ensure the long-term stable operation of E180-DTU
(ZG120-ETH). When the network port cannot receive data for a long time or the network has not received data for a long
time, E180-DTU (ZG120- (ETH) will restart after exceeding the set time so as to avoid abnormal conditions affecting
communication. The timeout restart can be set via the web page. The normal working time of this function is set to 60 ~
65535S, and the default value is 3600S. 0 is off,and it returns to the default value when the setting exceeds the range.

3.3.8 Clear cache

When TCP connection is not established, the data received by DTU will be placed in the cache area. E180-DTU
(ZG120-ETH) receiving cache is 2Kbyte. After TCP connection is established, the network cache data can be set to be
cleared according to customer needs.
The device has two cache areas, namely the serial data cache area and the network data cache area. When SOCKET
clear cache function is enabled, only the cache data of the relevant SOCKET link will be cleared and the serial port cache
data will not be cleared.