Mechanical design

3
Mechanical design
3.1

Cabinet mounted design

General instructions regarding the cabinet mounting of the liquid cooled S120 power
units of the chassis version you will find in chapter "Control cabinet construction and
EMC (particularly the chapter "Vertical installation ") of equipment manual Sinamics
S120 Power units / Chassis / Liquid-cooled.
3.2
Mechanical design of the marine-type cabinet
The high loads / demands in the marine area require an adaption of the mechanical
design of the cabinet. Possibilities to increase the mechanical stability of the cabinet
and the stable mounting of the power units into the cabinet are demonstrated in the
following pictures and the following description.
Fig. 1: Cabinet setup with mounting plate fixed to the side of the cabinet
Legend (refers also to Fig.2)
- Montageplatte für rückseitige Montage der Leistungsteile
- Montagewinkel für Auflage Leistungsteil
- Streben in die Schranktiefe
- Verstärkung des Schranks im Bodenbereich
- Türversteifungsrahmen-
Instruction for installation of the liquid-cooled chassis of Sinamics S120 power units into cabinets for marine drive applications,
8
:
- Mounting plate for backside mounting of the power units
- Mounting brackets for the support of power unit
- Struts mounted in the direction of cabinet depth
- Reinforcement of the cabinet in the floor area
- Door stiffening frame