Eaton Cooper Power Systems LCR 6200 RFN Instructional Leaflet page 6

Load control switch
Table of Contents

Advertisement

LCR 6200 Radio Frequency Load Control Switch (Brazil)
LCR 6200 RFN LEDs
LCR LEDs
The three LCR LEDs have the following meanings:
Load Status (Red)
LED Off – LED is off when the load is not being
controlled.
LED On – LED is on when the relay is activated
and the load is being controlled.
On-Board Radio Status (Green)
LED Off – LED is off during normal operation when
an RF SelectCom module is installed.
LED Blink On Startup – LED blinks three times on
a successful startup and the LCR executes a 50%
duty cycle for 6 seconds.
RF Radio Status (Yellow)
LED On – LED is on solid when the RF SelectCom
module has sent a valid ExpressCom message to
the LCR board.
LED Slow Blink – LED blinks slowly if a valid
ExpressCom message has not been received
from the RF SelectCom module in more than 2
hours.
6
RF SelectCom LEDs
The two RF SelectCom Module LEDs have the
following meanings:
Status (Blue)
LED On During Startup – LED is on solid for 30
seconds during startup, then it turns off.
LED On – LED is on solid when an RF radio
message is being transmitted or received in a
connection.
NOTE: The blue LED is not illuminated when a
broadcast message is being received.
Status (Green)
LED Off – LED is off when the RF SelectCom
module has lost power or when the RF SelectCom
firmware has malfunctioned.
LED On – LED is on solid when the RF SelectCom
firmware has malfunctioned.
LED Blinking – LED blinks (1/2 second on and 1/2
second off) when the RF SelectCom module has
power and it is functioning normally.
Instructional Leaflet