Fuse Protection Table - Daikin LXE10E-A14 Service Manual

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru

7.11 Fuse protection table

Fuse 1 (250V, 10A)
Fuse 2 (250V, 10A)
Fuse 3 (250V, 10A)
Fuse 4 (250V, 10A)
Fuse 5 (250V, 10A)
Fuse 6 (250V, 10A)
Fuse 7 (250V, 5A)
Protection of:
• High pressure switch (HPS)
• Compressor contactor (CC)
• Evaporator fan contactor high speed (EFH)
• Evaporator fan contactor low speed (EFL)
• Condensor fan contactor (CFC)
• Compressor terminal protector (CTP)
• Phase correction contactor (PCC1, PCC2)
• Gas bypass solenoid valve (BSV)
• Defrost solenoid valve (DSV)
• Hot gas solenoid valve (HSV)
• Liquid solenoid valve (LSV)
• Injection solenoid valve (ISV)
• Economizer solenoid valve (ESV)
• Electronic expansion valve (EV)
• PT and CT board
• Recorder
• LED indication
• LCD display
• Remote monitoring receptacle (RM)
• Suction modulating valve (SMV)
Drawing 7.12 at TB1 print board
page 7-8
Drawing 7.12 at TB1 print board
page 7-8
Drawing 7.12 at TB1 print board
page 7-8
Drawing 7.12 at TB1 print board
page 7-8
Drawing 7.12 at TB1 print board
page 7-8
Drawing 7.12 at TB1 print board
page 7-8
Drawing 7.12 at EC6 print board
page 7-8
7-7