Installation Instructions; General Information; Installation Of Sink& Shower Unit 3 Kw - 9.5 Kw; Correct Installation - Ariston AURES S 3.5 COM PL Manual

Instantaneous electric water heater
Hide thumbs Also See for AURES S 3.5 COM PL:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Installation Instructions:

THE GUARANTEE IS SUBJECT TO CORRECT INSTALLATION.
The instant water heater is a novel appliance designed to supply hot water instantly while conserving
energy. When the pressure switch is on, then the heating element heats the flowing water.

General information

1. The appliance must be installed and commissioned by a qualified technician in accordance with
established regulations and local health and safety regulations.
2. It is recommended that a residual current device(ELCB)will be incorporated in the circuit.
3. Installation of water pipeline must be completed prior to the installation of the heater and must be
checked to assure that there are no water leaks.
4. This appliance requires water pressure of minimum 0.3 bar. The appliance must be installed
horizontally where water supply comes from the left side.
5. WARNING! You must use only the supplied outlet accessories. The water outlet should always be
left open as the operating principle is based on an open water outlet.
6. Without supervision the use of the appliance by young children or infirm person is forbidden.
Playing with the unit by young children is forbidden.
Installation of sink& shower unit 3 kW - 9.5 kW
1. The shower unit should be installed on the wall.
2. Remove cover in order to connect the electric cable to the terminal block inside the unit.(unscrew
4 screws)
3. The unit should have a separate electric cable in the switch board (see table 2)
4. The recommended electric cable for 2-Phase unit up to 9.5kW is 5 x 4.0mm
5. A 110V/5kW device must be connected to a separate 40A fuse and a feeding cable of 3X6 mm
6. Connect the appliance to the water network and check if there are no leaks as soon as the unit is
connected. Use the hoses supplied with the appliance, do not re-use old hoses
7. After connecting the water inlet to the unit, connect the electric cable to the designed terminal
blocks. The appliance must be earthed and the earth cable (show with a letter in the drawing) is
fixed to the terminal marked by the symbol
WARNING! The appliance must be grounded
8. The unit must be connected to the electric supply by a 2-pole
switch (for one phase unit) and to the multi-pole switch (in
case of multi phase unit)
9. Before performing any operations, disconnect the appliance
from the electricty mains using the external switch then
connect the power to cable to the appliance.
10. Connect the electric cable with the designated clamp.
11. Return the cover (4 screws)

Correct Installation

Sink
AURES
SLIM
Water
Inlet
Faucet
Shower
AURES
SLIM
Water
Water
Outlet
Inlet
Faucet
.
Water
Outlet
5
2
Incorrect Installation
Danger!!!
Incorrect Installation
AURES
SLIM
EN
2
.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents