Ariston ST 100 ProTech Instructions For Installation, Servicing And Use

Ariston ST 100 ProTech Instructions For Installation, Servicing And Use

Unvented hot water storage cylinders

Advertisement

Unvented Hot Water Storage
Cylinders
Instructions for Installation,
Servicing and Use
Country of destination: GB/IE

Advertisement

Table of Contents
loading

Summary of Contents for Ariston ST 100 ProTech

  • Page 1 Unvented Hot Water Storage Cylinders Instructions for Installation, Servicing and Use Country of destination: GB/IE...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS THE BENCHMARK SCHEME Page 2 GENERAL INFORMATION Page 3 Guarantee Page 3 How the Appliance Works Page 3 Delivery Page 4 INSTALLATION Page 5 Water Regulations Page 5 Building Regulations Page 5 General Guidance Page 5 Cold Water Supply Page 5 Siting and Fixing Page 6...
  • Page 3: General Information

    Failure to do so may invalidate the guarantee. When installing and servicing the cylinder, Ariston Thermo UK Ltd recommend the use of protective clothing i.e. gloves. The Ariston range of unvented cylinders come with varying guarantees uArAntee depending on the model of cylinder.
  • Page 4: Delivery

    These comprise a combined line strainer/pressure reducing valve and core non-return valve/expansion relief valve. The Ariston range of Unvented Cylinders are available in the following elivery options: The Wall-hung ProTech cylinder (100 litre model), which is supplied as follows;...
  • Page 5: Installation

    INSTALLATION The appliance should be installed in accordance with the Domestic Heating Compliance Guide. These regulations (byelaws in Scotland) ensure a good supply of Ater eGulAtions wholesome water, and that only approved materials, pipes and fittings are used to convey water. These are a statutory document and take priority over all other regulations uilDinG eGulAtions...
  • Page 6: Siting And Fixing

    : In the event that the installation of this cylinder wil require a third MportAnt sensor to be fitted (i.e. Solar) please also refer to Section 3.3 General Guidance options A and B (page 5) of this manual. For further technical advice, please contact the Ariston Technical Advice Line on 0870 241 8180.
  • Page 7: Overall Dimensions

    verAll iMensions...
  • Page 9 The taps must be a minimal size of at least 15mm nominal size (preferably 22mm), and manufactured in accordance with BS 2879:1980. When installing the expansion vessel Ariston recommend it be connected directly to the combination valve (see Figs 3.9 - 3.10). MportAnt...
  • Page 10 st p stD 125-150-210-300 D irect COLD PRESSURE + TEMPERATURE MAINS-IN RELIEF VALVE 22mm COMBINATION VALVE COLD MAINS-IN 15/22mm EXPANSION VESSEL COMBINATION VALVE 15mm EXPANSION PRESSURE + TEMPERATURE VESSEL RELIEF VALVE HOT SUPPLY 22mm HOT SUPPLY 15/22mm EXPANSION RELIEF PIPE EXPANSION RELIEF PIPE...
  • Page 11 itD 130-150-215-305 D iti 80-130-150-215-255-305 i irect nDirect COLD COLD MAINS-IN MAINS-IN 22mm 22mm COMBINATION COMBINATION VALVE VALVE EXPANSION EXPANSION VESSEL VESSEL HOT SUPPLY 22mm PRESSURE + PRESSURE + TEMPERATURE TEMPERATURE RELIEF VALVE RELIEF VALVE HOT SUPPLY 22mm EXPANSION RELIEF EXPANSION RELIEF PIPE PIPE...
  • Page 12: Cold Water Combination Valve

    The cold water combination valve may be fitted in close proximity to the Ater cylinder, or alternatively, it may be separated to allow the pressure reducing oMBinAtion Alve valve where the mains supply enters the property allowing for balanced cold water throughout the whole property whilst the 6 bar safety valve is fitted in close proximity to the cylinder.
  • Page 13 3/4” B.S.P. CONNECTION FOR EXPANSION VESSEL 22mm COLD 22mm TO WATER HEATER MAINS IN 15mm EXPANSION RELIEF OUTLET TO TUNDISH SERVICEABLE 3/4” PRESSURE REDUCING CARTRIDGE AND LINE STRAINER (SET AT 3.5 BAR) EXPANSION RELIEF VALVE (SET AT 6 BAR) MPORTANT The connecting nut used on this water group is of an eccentric design.
  • Page 14: Connection To Services

    3.10 It is recommended that a 22mm pipe run should supply the outlets onnection to ervices throughout the building, especially to baths and showers. Short runs of 15mm pipe may be used to connect basins and sinks. 3.11 On floor-standing models a secondary return may be fitted (consult the label econDAry eturn on the face of the unit for the correct location).
  • Page 15 The single common discharge pipe should be at least one pipe size large than the largest individual discharge pipe to be connected. If unvented hot water storage systems are installed where discharges from safety devices may not be apparent i.e. in dwellings occupied by the blind, infirm or disabled people, consideration should be given to the installation of an electronically operated device to warn when discharge takes...
  • Page 16 workeD exAMple The example below is for a G1⁄2 temperature & pressure relief valve with a discharge pipe (D2) having 4 no. elbows and length of 7m from the tundish to the point of discharge. From t ABle Maximum resistance allowed for a straight length of 22mm copper discharge pipe (D2) from G1⁄2 temperature &...
  • Page 17: Electrical Connection

    The electrical installation must be in accordance with the current I.E.E. 3.13 e lectricAl wiring regulations. onnection protecH electronic Anti-corrosion systeM (st 100 models only) : The ProTech anti-corrosion system MUST be permanently MportAnt connected to a fused non-switched 240V electricity supply. The ProTech system, an exclusive solution, is an electronic anti-corrosion protection system which ensures maximum longevity of the appliance.
  • Page 18 systeM A systeM B . 3.12...
  • Page 19: Electrical Diagrams

    3.14 Should the Economy 7 system not to be used, a separate 13 amp supply to lectricAl iAGrAMs each element will be required through a double pole fused isolating switch having a contact gap of at least 3mm on each pole.The immersion heater shall be installed with 85°C rubber insulated HOFR-sheathed flexible cable complying with Table 8 of BS 6141: 1991.
  • Page 20 . 3.15 MpORTANT HEN WIRING THE LITRE CYLINDERS IMMERSION HEATER ENSURE THAT A SUITABLE HEAT RESISTANT CABLE RATED ABOVE THE PROTECTIVE DEVICE IS USED MM FOR...
  • Page 21 Wiring diagram for two 2 Port Valves with Ariston GENUS HE, CLAS HE and CLAS boilers with 2 zone clip in fitted. . 3.16 itsi  itH reGArDs to tHe AQuABrAvo cylinDers For More DetAileD wirinG instructions pleAse contAct 0870 241 8180.
  • Page 22 Wiring diagram for two 2 Port Valves . 3.16 itsi  note itH reGArDs to tHe riMo cylinDers More DetAileD wirinG instructions pleAse contAct 0870 241 8180. tHe tecHnicAl DepArtMent on...
  • Page 23 Wiring diagram for a 3 Port Valve & 2 Port Valve . 3.17...
  • Page 24: Commissioning

    COMMISSIONING The thermostat(s) on the immersion heater(s) should be adjusted to trip at 60-65°C. This is the ideal temperature to prolong element life in hard water areas. Scale on the sheath builds up more rapidly at temperatures above this causing the element to overheat and premature failure can occur. Higher temperatures without additional controls would result in scalding.
  • Page 25 10) Test the operation of the temperature & pressure relief and expansion valves by lifting/turning the manually operated test lever/cap and observing that water flows through freely and safely to waste; 11) Check that the discharge pipe is plumbed so that it falls continuously and that no taps, valves or other shut off devices are installed in the pipe;...
  • Page 26: Maintenance

    MAINTENANCE To ensure efficient and safe operation, and to maintain the warranty, it is necessary to ensure the appliance is serviced annually by a competent person. Before servicing, preliminary electrical system checks must be carried out to ensure electrical safety (i.e. polarity, earth continuity, resistance to earth and short circuit).
  • Page 27: Thermal Cut-Out(S)

    closes after testing); 4) Expansion relief valve - check manually by turning the test knob (ensure valve closes after testing); 5) Discharge pipes (D1) - from both temperature & pressure relief and expansion relief valve for obstructions; 6) Tundish & discharge pipe (D2) - open either valve gradually to produce a full bore discharge into tundish and D2 without any back pressure;...
  • Page 28: Unvented Controls

    unvented controls(s) Check controls as per the following: 1) Line strainer - with the water supply turned off remove screen from strainer and clean of any detritus; 2) Expansion vessel - with the water supply turned off and taps open, check expansion vessel pressure and top up as necessary;...
  • Page 29: Fault Finding

    FAu LT FINd ING FAult possiBle cAuses reMeDy 1) Mains cold water Check and open Isolating supply shut off and/or stop valve. Check water, Local Water Authority no Hot wAter 2) Line strainer Turn off mains water supply, Flow blocked remove line strainer and clean 3) Cold Water...
  • Page 30 TECh NICAL d ATA Maximum Water Supply Pressure* Operating Pressure Expansion Vessel Charge Pressure Expansion Relief Valve Setting Pressure & Temperature Relief Valve Setting bar/°C Pressure Reducing Valve Set Pressure Electrical Supply Immersion Heater Rating Immersion Heater Type Immersion Heater Reference Number Maximum Primary Pressure Heat Exchanger Performance Coil Surface Area...
  • Page 31 Maximum Water Supply Pressure* Operating Pressure Expansion Vessel Charge Pressure Expansion Relief Valve Setting 7/90 7/90 Pressure & Temperature Relief Valve Setting bar/°C 7/90 7/90 7/90 7/90 7/90 7/90 7/90 7/90 7/90 7/90 7/90 Pressure Reducing Valve Set Pressure Electrical Supply Immersion Heater Rating Immersion Heater Type Immersion Heater Reference Number...
  • Page 34: Benchmark Commissioning Checklist

    BENCh MARK COMMISSIONING Ch ECKLIST...
  • Page 35: Benchmark Service Record

    BENCh MARK SERVICE RECORd...
  • Page 36 Ariston thermo Group, luce - France Manufacturer: Commercial subsidiary: Ariston thermo uk ltd Ariston Building Hughenden Avenue High Wycombe Bucks. HP13 5FT Telephone: (01494) 755600 Fax: (01494) 459775 Internet: www.ariston.co.uk E-mail: info.uk@aristonthermo.com technical service Hot line: (0870) 241 8180 customer service Help Desk: (0870) 600 9888...