Dss Tools - Bosch Servodyn-D Manual

With canrho interface, commissioning with dss
Table of Contents

Advertisement

4.3.2

DSS tools

Block diagram
x-Control: Position control
n-Control: Velocity control
i-Control: Current control (torque)
Click on one of the items to have the
DSS show detailed information.
Dimmed items cannot be changed.
1070 066 037-101 (00.02) GB
L
In order to change the parameters, you should use the DSS monitor or
L
Select the menu sequence
D DISPLAY " CONTROL " BLOCK DIAGRAM, or
D click on the
select "Control " Block diagram".
Title bar
Get:
Import:
Export:
command button in the DSS basic image and then
The DSS reads all relevant parameters from the drive.
The DSS reads all relevant parameters from a file.
If the specified file does not contain all required parameters, the
DSS will first use the current parameter values or system de-
fault values.
In addition to the "Block diagram" text, the path and name of the
specified file will be displayed in the title bar.
If only the "Block diagram" text is displayed in the title bar, you
may save the current settings in a new file.
If the path and name of a file is displayed in the title bar in addi-
tion, the DSS will save the current settings in this file and re-
place the previous values.
Initial commissioning
Read data from
drive
Read data from
file
Write data to
file