Displaying I/O Signals - Bosch Servodyn-D Manual

With canrho interface, commissioning with dss
Table of Contents

Advertisement

Diagnoses
6–4
6.3

Displaying I/O signals

Display of all input signals con-
figured in P-0-2000.
The current status of the sig-
nals is derived from P-0-2001.
Display of all output signals con-
figured in P-0-2002.
The current status of the signals
is derived from P-0-2003.
The DSS shows you
D the signals assigned to the digital inputs and outputs of the inverter, and
D the current status of these signals.
For the assignment of individual signals to the digital inputs and outputs of
the inverter, please refer to section 4.2.8 on page 4–8 ff.
L
Select the menu sequence:
D DIAGNOSES " I/O SIGNALS, or
D click on the
select "I/O Signals".
The DSS indicates a HIGH level by the "n" character in the checkbox.
Dimmed checkboxes indicate that the corresponding bit has not been as-
signed to a signal in P-0-2001.
The data display is updated in the intervals set for the "Module status dis-
play" (cf. page 6–3).
command button in the DSS basic image and then
1070 066 037-101 (00.02) GB

Advertisement

Table of Contents
loading

Table of Contents