Evu/Sg Wiring Diagram For The Indoor Unit With An Integrated Electric Booster Heater; 11.3.7 Photovoltaic; Kabelplan; Measurements From Temperature Sensors - Bosch Compress 3000 AWES 2-6 Installation Manual

Indoor unit for air to water heat pump
Table of Contents

Advertisement

Technical information
11.3.6 EVU/SG wiring diagram for the indoor unit with an
integrated electric booster heater

11.3.7 Photovoltaic

Since there are only two external inputs for the energy supplier and PV,
these cannot be used at the same time.
PV connection to external input 1 or 4.
The heat pump is able to process a control signal of a PV system.
11.4

Kabelplan

Designation
3-way valve
VW1
Pump 1. HC
PC1
DHW pump
PW2
Signal cable IDU - ODU
CAN-BUS
Power supply
IDU AWE/
AWM/AWMS
Power supply
IDU AWB
Heating cable
EMS - Module
MM100,
MS100..
0-10V control boiler
EM0
PV-Function
Smart Grid
EVU-block
Table 11 Connections in indoor units IDU AWE/AWM/AWMS and AWB
Sensor
Designation
Outdoor
T1
Flow
T0
Hot water (DHW)
TW1
Dew sensor
MK2 (max. 5x)
Mixed heating circuit
TC1
Pool temperature
TC1
Table 12 Cable plan sensor
11.5

Measurements from temperature sensors

32
min. cross-
type of cabel
section
3 x 1,5mm²
cable integrated
3 x 1,5mm²
H05VVF
3 x 1,5mm²
H05VVF
2
2 x 2 x 0,75mm
LIYCY (TP)
5 x 2,5mm²
NYY
3 x 1,5mm²
NYY
3 x 1,5mm²
NYY
0,5mm²
J-Y (ST)Y 2 x 2 x 0,6
2
2 x 2 x 0,75mm
LIYCY (TP)
0,4mm²
J-Y (ST)Y 2 x 2 x 0,6
0,4mm²
J-Y (ST)Y 2 x 2 x 0,6
3 x 1,5mm²
H05VVF
min. cross-
type of cabel
section
2
0,5 mm
J-Y (ST)Y 2 x 2 x 0,6
2
0,5 mm
J-Y (ST)Y 2 x 2 x 0,6
2
0,5 mm
J-Y (ST)Y 2 x 2 x 0,6
2
0,5 mm
cable integrated
2
0,5 mm
J-Y (ST)Y 2 x 2 x 0,6
2
0,5 mm
J-Y (ST)Y 2 x 2 x 0,6
If the PV system has sufficient current for operating the heat pump, it can
communicate this information to the heat pump in the form of a start
command via a control cable. The control cable must be connected to
one of the available external connections. The selected external
connection must be configured in the control unit for the PV function.
The heating system must have a buffer cylinder and only heating circuits
with a mixer in order for a start command to be effective. A start
command causes the buffer cylinder to be charged up to the maximum
temperature achievable by the heat pump. However, it can only be
charged when the temperature in the buffer cylinder is below the
maximum temperature. Otherwise, the heat pump remains off.
max. length
connected at:
Indoor unit
Indoor unit
30m
Indoor unit
Indoor unit
3m
Indoor unit
100m
Indoor unit
Indoor unit
(IDU AWB)
From inverter on terminal I1 or I4 in IDU,
From load management controller on terminal I4,
From load management controller on terminal I1,
max.
connected at:
length
Indoor unit
Indoor unit
Indoor unit
Indoor unit
100m
MM100
100m
MP100
Compress 3000 AWES – 6720892204 (2020/06)
connection
Power source
terminal:
53 / 54 / N
IDU
52 / N / PE
58 / N / PE
Can High 31(H)
2-wire
Can Low 32(L)
connection,
12V not
shielding in both
connected
ends
sub-distribution
3 x C16
L / N / PE
sub-distribution
1x C16
56 / N / (HC /
IDU / HC / HC
HC)
19 / 20
38 / 39
EVU-block or Smart Grid
connection 49, 50 in IDU
connection 13, 14 in IDU
connection
Power source
terminal:
3 / 4
1 / 2
5 / 6
34 / 35
1 / 2
1 / 2