400 V~ 3N Indoor Unit With 230 V~ 1N Outdoor; Unit - Bosch Compress 3000 AWES 2-6 Installation Manual

Indoor unit for air to water heat pump
Table of Contents

Advertisement

Technical information
11.3.4 400 V~ 3N indoor unit with 230 V~ 1N outdoor unit
Fig. 32 400 V~ 3N indoor unit with 230 V~ 1N outdoor unit
[A]
indoor unit
[B]
outdoor unit
[1]
Installer module SEC 20
[2]
Pressure switch
[3]
9 kW electric heater
[4]
3x1 kW (3x53 Ω)
[5]
3x2 kW (3x27 Ω)
[6]
Relay 1 (K1)
[7]
Relay 2 (K2)
[8]
Relay 3 (K3)
[9]
Overheating protection
[10] Indoor unit terminals
[11] 400 V ~3 N power supply for indoor unit
[12] 230 V ~1 N power supply for outdoor unit
30
[13] 230 V ~1 N power supply for heating cable
[14] 230 V ~1 N power supply EMS (accessories)
[15] Outdoor unit terminals
[16] outdoor unit
[17] Screened CAN bus line 2 x 0.75mm
[18] EMS module (accessory)
The output of the electric booster heater must be limited to a maximum
of 6 KW with the configuration in parallel mode with the heat pump.
Compress 3000 AWES – 6720892204 (2020/06)