Atmor ThermoPro Series Manual page 11

Electric tankless water heaters
Table of Contents

Advertisement

Electrical Specifications by Heater Input
Item #
AT-910-18TP
AT-910-24TP
AT-910-27TP
Power Rates
Item #
AT-910-18TP
18,000 Watts
AT-910-24TP
24,000 Watts
AT-910-27TP
27,000 Watts
Wiring Diagram for AT-910-18TP, AT-910-24TP, AT-910-27TP,
Circuit Breakers
L1
L2
L1
Unit Requires 10 AWG ground wire - one for each 240V circuit
Your tankless water heater is now installed and ready to use! Follow the General Operating
Instructions to complete the setup.
kW
Max
Required Breaker
Amps
18
75 A
3 x 30A double Pole
24
100 A
3 x 40A double Pole
27
112.5 A
3 x 40A double Pole
240V
220V
150,125 Watts
20,166 Watts
22,687 Watts
L2
L1
L2
8/2 AWG
8/2 AWG
8/2 AWG
Req. Wire Size
3 x 8 AWG with ground
3 x 8 AWG with ground
3 x 8 AWG with ground
208V
13,520 Watts
18,026 Watts
20,280 Watts
Terminal Block in Unit
L1 L2
L1 L2
L1 L2
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

At-910-18tpAt-910-24tpAt-910-27tp

Table of Contents