Manufacturer:
Gebr. Brasseler GmbH & Co. KG
Trophagener Weg 25
32657 Lemgo · Germany
ER C-Post
®
© 08/2012, Gebr. Brasseler GmbH & Co. KG
304851 - Rev 08/2012
ö ê í
¿
Order number
Numéro d'ordre
Número de pedido
©
Post systems
Systèmes de reconstitution
Sistemas de postes
Fig. 1
Fig. 2
Size
Colour: yellow
Taille
Couleur: jaune
050
Tamaño
Color: amarillo
Pilot drill · Foret pilote · Fresa piloto
1.000 - 5.000 rpm
(
183LB.204
20.000 rpm
)
Reamer · Elargisseur · Ensanchador
1.000 - 2.000 rpm
(
196.204
20.000 rpm
)
Reamer, long · Elargisseur, long · Ensanchador, largo
1.000 - 2.000 rpm
(
196L.204
20.000 rpm
)
Universal depth gauge · Calibre de profondeur universal · Calibre de profondidad universal
74L12
Root facer · Alésoir à surfacer · Abrasivo para planear
2.000 rpm
(
120D.204.030 )
20.000 rpm
Roughening instrument · Instrument à rugosifier · Asperizador
196D.644
C-Post
®
= 231L12.000
Tab. 1
ö
ER C-Posts
for preprosthetic reconstruction
®
1. Components of the system
See table 1
2. Indication
- There must be sufficient healthy tooth sub stance for a complete circular preparation.
2.1 Preprosthetic stabilization of devitalized abutment teeth having a substantially intact clinical crown (Fig. 1).
(Degree of destruction 0 -10 %)
2.2 Preprosthetic reconstruction of devitalized abutment teeth with partially destroyed clinical crown, direct
approach using plastic materials (Fig. 2). (Degree of destruction 10 - 70 %)
2.3 Preprosthetic reconstruction of devitalized abutment teeth with destroyed clinical crown, indirect approach
using ceramic materials (Fig. 3). (Degree of destruction 70 - 100 %)
3. Contraindication
- Teeth with completely destroyed crown, no supragin gival tooth substance available.
4. General preparatory treatment
4.1. The tooth or root has been prepared and endo dontically treated according to the indication.
4.2 Choose the corresponding C-Post
root post.Using the radiograph determine the post diameter according to
®
the anatomic situation of the tooth.
4.3 Removal of the root filling app. 4 mm short of the apex with pilot drill 183LB or the selected post size 050,
070, 090 or 110.
- Mark the required preparation length on the pilot drill using depth gauge 74L12Speed for engine operation:
1.000 - 5.000 rpm
4.4 Enlarge root canal with the respective reamer 196 corres ponding to the selected C-Post
If clinical crown is still available, use reamer 196L
- Mark the required preparation length on the pilot drill using depth gauge 74L12
- Speed for engine operation: 1.000 - 2.000 rpm
4.5 Control proper fit by inserting the selected post.
5. Procedure according to indication
5.1 Preprosthetic stabilization (indication 2.1)
5.1.1 Mechanical conditioning of the canal wall with roughening instrument 196D
- Rotate instrument in the root canal without applying pressure (2 - 3 rotations).
5.1.2 Rinse canal and dry
5.1.3 Cleaning the post surface
- Cleaning with medical alcohol
- Again blasting with aluminium oxide (50 µm)
5.1.4 The post is cemented using the adhesive technique
- Chemical conditioning of the dentin with bond-assisting agent (e.g. ED Primer
- Coat C-Post
with self-curing composite (e.g. Panavia
®
- Insert C-Post
slowly into the root canal and press with thumb into final position
®
- Curing of the composite and if necessary removal of excess.
5.1.5 Completing the definite preparation5.2 Plastic buildup (indication 2.2)
5.2.1 Mechanical conditioning of the canal wall with roughening instrument 196D
- Rotate instrument manually in the root canal without applying pressure (2 - 3 rotations).
5.2.2 Rinse canal and dry
5.2.3 Cleaning the post surface
- Cleaning with medical alcohol
- Again blasting with aluminium oxide (50 µm)
5.2.4 Cementing post using the adhesive method
- Chemical conditioning of the dentin with a bond-assisting agent (e.g. ED Primer
- Coat C-Post
with self-curing composite (e.g. Panavia
®
- Insert C-Post
slowly into the root canal and press into final position with thumb
®
5.2.5 Adaptation of the plastic core material (e.g. Clearfil PhotoCore
5.2.6 Curing and completing the definite preparation
5.3 Ceramic buildup (indication 2.3)
5.3.1 Preparation of the central inlay cavity (maximal depth 1 mm)
- If root cross-section is large enough, use root facer 120D.204.030
- Speed for engine operation: 2.000 rpm
- or cylindrical diamond instruments, e.g. 835KR
Distributor/Importer for USA and Canada:
Komet USA LLC
3042 Southcross Blvd, Suite 101
Rock Hill, SC 29730, USA
Phone: 888-566-3887
Fax:
800-223-7485
info@kometusa.com
www.kometusa.com
CAUTION: U.S. Federal law restricts the device
to sale by or on the order of a licensed dentist.
|
LOT number
Numéro de lot
Número de lote
=
Do not re-use! (single use only)
Ne pas réutiliser (usage unique)
No reutilizar (un solo uso)
Fig. 3
Size
Colour: orange
Taille
Couleur: orange
070
Tamaño
Color: naranja
1.000 - 5.000 rpm
(
183LB.204
20.000 rpm
)
1.000 - 2.000 rpm
(
196.204
20.000 rpm
)
1.000 - 2.000 rpm
(
196L.204
20.000 rpm
)
196D.644
= 439L12.000
, Kuraray)
®
F2.0, Kuraray)
®
, Kuraray)
®
F2.0, Kuraray)
®
, Kuraray)
®
Instructions for use
Please read carefully and retain for future reference.
Conseils d'utilisation
A respecter scrupuleusement et garder cette copie
pour une utilisation ultérieure.
Instrucciones de empleo
Leer detenidamente y guardar este ejemplar para
uso más tarde.
?
Consult instructions for use
Se reporter aux instructions
Observe indicaciones
Size
Colour: red
Taille
Couleur: rouge
090
Tamaño
Color: rojo
1.000 - 5.000 rpm
(
183LB.204
20.000 rpm
)
1.000 - 2.000 rpm
(
196.204
20.000 rpm
)
1.000 - 2.000 rpm
(
196L.204
20.000 rpm
)
196D.644
= 232L12.000
5.3.2 Impression of the temporary preparation with post inserted for the subsequent fabrication of the ceramic
buildup in the laboratory (e.g. with Permadyne
5.3.3 Temporary insertion of ER TMP posts while the ceramic buildup is made in the laboratory.
5.3.4 Fabrication of a two-piece ceramic buildup in the laboratory (for instance made of In-Ceram-Aluminia
In-Ceram-Spinell
, Vita or IPS-Empress Cosmo
®
5.3.5 Supply of the post buildup glued and blasted in the laboratory
5.3.6 Remove temporary restoratoration and clean canal
5.3.7 Mechanical conditioning of the canal wall with roughening instrument 196D
- Rotate instrument manually in the root canal without applying pressure (2 - 3 rotations)
5.3.8 Rinse canal and dry
5.3.9 Cement post buildup using the adhesive method
- Chemical conditioning of the dentin with bond-assisting agent (e.g. ED Primer
- Coat post portion with self-curing composite (e.g. Panavia
- Insert post buildup slowly into the post canal and press into final position with thumb
5.3.10 Curing and completion of definite preparation
6. Further treatment
6.1 For the definite preparation, please observe the following rules:
- Core has to be surrounded circularly
- For all-ceramic crowns we recommend the shoulder preparation
- The post stabilizes the root. The crown has to surround the root reinforced with a post in an at least 2 mm wide
parallel zone so that forces exerted are distributed on the entire tooth.
6.2 Impression and temporary restoration in the usual manner.
6.3 Fabricate and insert crown.
7. Recommendation for maintenance
®
All system components are supplied in non-ster ile condition. C-Posts
The instruments are to be disinfected with anticorrosive disinfecting and cleaning agents for rotary instruments.
Regarding recommendations for use (immersion time, concentration, suitability) of the disinfecting and cleaning
agents see manufacturers' instructions. Remove all residues of disinfecting and cleaning agent with water and
allow to dry (e.g. by air stream). Do not store instruments for a longer period in wet or humid condition. Make
sure that they do not come in contact with each other during ultrasonic cleaning! Inspect cleaned instruments
visually. Damaged and dull instruments must not be used any longer. Attention: The C-Posts
sterilized in the autoclave. Multiple sterilization has to be avoided.Sterilization of the instruments is carried out
using the known methods in the autoclave according to the specific provisions on the sterilization of medical
products in your country. The instructions of the respective device manufacturer have to be observed. After
sterilization, check instruments for defects on the surface. Corroded instruments must not be used any longer.
The operator of medical products is responsible for seeing that proper treatment is carried out by qualified
personnel using the appropriate materials and suited equipment.
8. Safety and liability
See also "Instructions for use and safety recommendations" in the KOMET USA LLC catalog and our webside at
www.kometusa.com. The user is responsible to check the products prior to use as to whether they are suited for
the intended purpose. C-Posts
corresponding original instruments according to these instructions. The manufacturer declines any liability or
compen sation for possible dam age due to the use of instruments which do not belong to the system and which
may impair the function.
9. Disclaimer of Warranties
ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRAN-
TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. ALL
INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOST PROFITS, INJURY TO
OTHER PROPERTY, LOSS OF USE OR OTHER COMMERCIAL LOSSES, ARE EXPRESSLY DISCLAIMED. If, not with-
standing the foregoing, consequential and incidental damages cannot be excluded due to operation of law, such
damages are expressly limited in amount to the purchase price of any defective products.
Store out of children's reach.
For dental use only..
Packing unit
/
Unité d'emballage
Unidad de embalaje
Size
Colour: blue
Taille
Couleur: bleu
110
Tamaño
Color: azul
1.000 - 5.000 rpm
(
183LB.204
20.000 rpm
)
1.000 - 2.000 rpm
(
196.204
20.000 rpm
)
1.000 - 2.000 rpm
(
196L.204
20.000 rpm
)
196D.644
= 233L12.000
, Espe)
®
, Ivoclar).
®
F2.0, Kuraray)
®
®
are part of the ER root post system and should only be used with the
®
Material
Matériau
Material
Stainless Steel
Acier inoxydable
Acero inoxidable
Stainless Steel
Acier inoxydable
Acero inoxidable
Stainless Steel
Acier inoxydable
Acero inoxidable
Stainless Steel
Acier inoxydable
Acero inoxidable
Stainless Steel · diamond coated
Acier inoxydable · diamanté
Acero inoxidable · diamantado
Stainless Steel · diamond coated
Acier inoxydable · diamanté
Acero inoxidable · diamantado
Zirkonium-oxide ceramics, roughened
surface · Céramique à l'oxyde de
zirconium, surface rugosifiée ·
Cerámica de óxido de circonio,
superficie asperizada
,
®
, Kuraray)
®
can be disinfected with medical alcohol.
can only be
®