INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Air filter
6
Filter
5
Filter
3
Batteries
2
Wireless remote control
7
Mounting screw
CAUTION
Install in rooms that are 13 m
3
If a leak of refrigerator gas occurs
inside the room, an oxygen deficiency
can occur.

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
Liquid side : Ø6.35 mm
Gas side
: Ø9.52 mm
A
(RAS-10, 13J2FVG-TR)
: Ø12.7 mm
(RAS-18J2FVG-TR)
Pipe insulating material
B
(polyethylene foam, 8 mm thick)
C
Putty, PVC tapes
50 mm or more
8
Flat head
wood screw
9
Insulation sheet
or larger.
Q'ty
One
each
1
One
each
1
Installation plate
50 mm or more
Shield pipe
4
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
Saddle
Extension
drain hose
(Not available,
provided by installer)
Fixing bolt arrangement of outdoor unit
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed
to a strong wind.
Use Ø8 mm or Ø10 mm anchor bolts and nuts.
If it is necessary to drain the defrost water, attach drain nipple 0 and cap water
proof ! to the bottom plate of the outdoor unit before installing it.
108 mm
28 mm
Air outlet
When using a multi-system outdoor unit is used, refer to the installation manual
provided with the model concerned.
6
Do not allow the drain hose to get
slack.
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left, rear
right, right, bottom right or bottom
left.
Right
Rear right
Bottom right
Insulate the refrigerant pipes
separately with insulation, not
together.
8 mm thick heat resisting
polyethylene foam
In case of right or left piping
125 mm
Air inlet
*
90 mm
600 mm
Drain outlet
Cut the piping
hole sloped
slightly.
Left
Rear left
Bottom left
Cut dot-line area
Drain nipple and cap
water proof are packed
in outdoor unit.