Control Box
Post Bracket
120 Volt indoor
Transformer
(surge protector
not supplied)
Run 1000' (max.) of low
voltage wire to control
box from transformer
(wire not included).
This product meets the requirements of UL325, the standard for gate operator safety.
For Online Technical Support 24 hour/day, 7 day/week visit
For more information on Mighty Mule's full line of Automatic Gate Operators and
Mighty Mule® is the retail brand of Nortek Security & Control, LLC
Copyright
©
2019 Nortek Security & Control, LLC
Installation Manual
Gate Swings Evenly and Freely
Hung Firmly and Plumb
First Gate Opener
Gate Bracket
Horizontal Support
Power Cable
PVC conduit (not included)
to run second opener power
cable under driveway.
Example of finished installation
(installations vary slightly on different types of gates)
NSC Sales: 800-543-4283 • Fax 850-575-8912
NSC Technical Service 800-543-1236
Access Controls visit
HD272
Warning Sign
Second Gate Opener
Gate Bracket
Horizontal Support
Fence Post Set in Concrete
www.mightymule.com
www.mightymule.com
Post Bracket
10022516 A

Advertisement

Table of Contents
loading

Summary of Contents for Nortek Security & Control Mighty Mule HD272

  • Page 1 HD272 Installation Manual Gate Swings Evenly and Freely Control Box Hung Firmly and Plumb Warning Sign First Gate Opener Second Gate Opener Post Bracket Gate Bracket Gate Bracket 120 Volt indoor Post Bracket Transformer (surge protector Horizontal Support Horizontal Support not supplied) Power Cable Fence Post Set in Concrete...
  • Page 2: Table Of Contents

    Table of Contents WARNING Please Read This First! ..................... ii Manually Opening and Closing Gate................iii This equipment meets Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full Important Safety Information ..................
  • Page 3: Please Read This First

    Please Read This First! Important Safety Information Because automatic gate operators produce high levels this manual cannot be completely exhaustive in Thank you for purchasing a Mighty Mule Gate The Mighty Mule Gate Operator features Dual Sense of force, consumers need to know the potential hazards nature.
  • Page 4: For The Installer And End User

    Important Safety Information Important Safety Information For the Installer and End User For the Installer and End User WARNING Typical Entrapment Zones are shown in the diagrams on page Zone 1 – leading edge of the gate and the fence post. Zone 2 –...
  • Page 5 Important Safety Information Important Safety Information For the Installer and End User For the Installer and End User III. After Installation 7. To operate this equipment safely, YOU must Mighty Mule gate operators utilize Dual Sense One or more edge sensors may be located at the Technology™...
  • Page 6: Installing Warning Signs And Pedestrian Gates

    Important Safety Information Important Safety Information Installing Warning Signs and Pedestrian Gates Required Safety Precautions for Gates Warning signs alert people of automatic gate operation and are required when installing Mighty Mule Automatic These warning labels should be found at the locations specified below. If any of them are missing, immediately Gate Operators.
  • Page 7: Technical Specifications

    Technical Specifications Before You Begin MIGHTY MULE HD272 DUAL GATE OPENER _____________________________________ _____________________________________ 1. Determine Charging Options for Battery: Transformer OR Solar DRIVE • Low friction screw drive (linear actuator) rated for -5 °F to +160 °F (-20 °C to +71 °C).
  • Page 8: Parts List - Opener And Mounting Hardware

    Parts List – Opener and Mounting Hardware 2. Check Direction of Gate Swing The Mighty Mule 272 is designed for PULL-TO-OPEN installations. PUSH-TO-OPEN installations require two Push-To-Open brackets [FM148]. Push-to-Open Installation WARNING Instructions begin on page Moving Gate Can Cause Injury Or Death KEEP CLEAR! Gate may move at any time.
  • Page 9: Tools And Materials

    Tools and Materials Installation Overview for Pull-To-Open Gates PUSH-TO-OPEN installation instructions begin on page Tools Needed: Example of an installation on a chain link fence: • Power Drill Gate Swings Evenly and Freely Control Box • Open End Wrenches — "...
  • Page 10: Installation Of The First Gate Opener

    Installation of the FIRST Gate Opener Install Post Bracket Assembly and Gate Bracket IMPORTANT: Determine which side of the driveway you will mount the control box. From this point on, the gate and gate Step 1 opener on the same side as the control box will be referred to as the FIRST gate and gate opener. The gate and gate opener on the Insert the "...
  • Page 11: Attach Opener Arm

    Step 5 Be sure the position of the gate opener and brackets Step 9 Gate in the EXAMPLES allows for 1" of clearance between the gate and the Drill " holes through post as marked. Fasten post bracket assembly to the TOP VIEW Post Bracket opener in both the open and closed position, while...
  • Page 12: Install The Closed Position Stop Plates

    Install the Closed Position Stop Plates Closed Position Stop Plate mounted on the SECOND GATE Step 4 The closed position stop plate is attached to the FIRST gate to help stabilize the gate leaf in the closed position. An optional low SIDE VIEW profile ground stop, when used with the closed position stop plate, provides a secure point for the SECOND gate to close against.
  • Page 13: Mount The Control Box

    Mount the Control Box Connecting the Battery Battery Step 4 Screw Placement Guides Verify that the ON/OFF switch is in the OFF position. Step 1 Mount the Battery Box using the screws (provided) or another secure mounting method. Connect the BATTERY WIRE HARNESS wires to the battery --- The battery/control box must be mounted at least 3 feet above the ground to protect it from RED wires to POSITIVE (+) battery terminal and BLACK wires to rain splash, snow, etc., and at least 3 feet from an AC power source to prevent electrical...
  • Page 14: Connect Opener Power Cables

    Control Box Connect Opener Power Cables Step 3 Step 1 Lay the measured length of low voltage wire STATUS First Gate Opener Bring FIRST power cable into the control box through a strain relief slot, 1st OPR. in a trench following a path from the selected OPEN <...
  • Page 15: Set The Closed Position Limit For Pull-To-Open Installation

    Step 6 At the AC outlet, strip " of insulation from the ends of the low voltage Set the CLOSED Position Limit for PULL-TO-OPEN wire. Attach these stripped ends to the transformer terminals. A dab of Installation household petroleum jelly on each terminal will help prevent corrosion. We suggest adding crimp on fork lugs to the end of each wire before attaching it Your transmitter must be able to operate the gate.
  • Page 16: Setting Dual Sense Detection And Auto Close Timer

    Setting Dual Sense Detection and Auto Close Timer MMT103 Transmitter Learning the MM103 With system off, press and hold the transmitter button you want to use, then STATUS turn on the system and keep holding the button until the system "beeps" once. 1st OPR.
  • Page 17: Push-To-Open Installation Instructions

    Step 3: Attach Opener Arm (page Push-To-Open Installation Instructions Step 4: Install Closed Position Stop Plates (page Step 5: Mount the Control Box (page PUSH-TO-OPEN gates open out from the property (opener arms extend to open). Push-To-Open Brackets are required for this type Step 6: Connect Opener Power Cables (page of installation, one for each gate [FM148]...
  • Page 18: Solar Panel Instructions

    Connecting Additional Devices Solar Panel Instructions Mighty Mule strongly recommends the use of additional obstruction detection devices however we do not endorse any specific brand names. Only use products that are listed to be in compliance with any applicable UL safety NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME! standards and national and regional codes.
  • Page 19: Control Box Cover - Final Step

    1st OPR. OPEN < JOG > CLOSE 2nd OPR. MAX OFF SEC. STALL FORCE AUTO CLOSE PWR. Troubleshooting Guide LIMIT Accessory Inputs REMOVE JUMPER FOR PUSH TO OPEN OPTION SAFETY: Typically for use with photo beam device, loop detector or other non-contact sensors If your gate opener does not function properly, use this guide or use the online troubleshooter located at SFTY.
  • Page 20: Maintenance

    Maintenance Accessories Please visit www.mightymule.com for photos and Monthly, test the obstruction and entrapment protection systems. detailed descriptions of Mighty Mule Accessories, Monthly, service the gate operator (make sure the power switch is OFF). Clean extended operator arm with a soft, dry clean cloth. After cleaning, apply a high quality silicon spray to a soft dry cloth and wipe the push/pull tube.
  • Page 21: Gate Operator Installation Checklist

    Accessories are Available From Your Retail Store (con't) Gate Operator Installation Checklist Low Voltage Wire (RB509) The 16 gauge, multi-stranded, dual conductor Low Voltage Wire is for connecting the AC powered The gate has been checked to make sure it is level and moves freely in both directions. ❑...
  • Page 22: Notes

    Notes Notes...
  • Page 23 VOLTAGE RATINGS 14 Vac Transformer _____________ 13.0 to 16.0 Vac 10 W Solar panel _______________ 18.0 to 22.0 Vdc 600 mA Measure voltage at panel and control box. 12 V Battery ____________________ 12.5 to 13.5 Vdc Charging circuit ________________ 13.8 to 14.8 Vdc Measure voltage at battery terminals with battery connected 800-543-4283 •...