Troubleshooting - AR Blue Clean MAXX 2100 Assembly, Care And Use Instructions

Psi electric pressure washer
Table of Contents

Advertisement

TROUBLESHOOTING

If you have any questions regarding the product, please call customer service at 1-866-235-5112
PROBLEM
Unit will not turn on.
The high pressure
(HP) hose will
not connect/stay
connected to the
spray gun. Is this a
spray gun problem?
The unit is running
but there is no water
TROUBLESHOOTING
Why is water leaking
where the high
pressure hose
connects to the spray
gun?
I can't remove the
lance from the spray
gun. What should I
do?
The power washer
turns on for
2 seconds, shuts
off, and will not turn
back on. Do I have a
defective unit?
16
95032_IM_MAXX2100_REV01_ENG-FR-SP.indd 16
CORRECTIVE ACTION
1. Make sure the power washer is OFF. Plug in the electrical cord to a grounded 120 volt
outlet (no electrical extension cord should be used). If the electrical cord will not plug
into your outlet, your electrical outlet is not properly grounded and should not be used.
Use another electrical outlet.
2. If this did not correct the problem, try plugging into another electrical outlet and repeat
the above procedure. If it is still not working, call Customer Service. 1-866-235-5112
1. In most cases, the spray gun is not the problem. The problem is the rubber sleeve
into the spray gun. It should "click" into place and will not come out until the hose is
released by pushing in the lever on the underside of the gun. You may cut away the end
of the sleeve with a sharp knife if unable to move the sleeve down. Be careful not to cut
or puncture the hose.
1. Power should NOT be turned on until water comes through the spray gun. Doing so will
damage the motor.
2. Check the water source.
3. Eject the nozzle from the lance to determine if clog is coming from the nozzle (If nozzle
is clogged, see nozzle cleaning instructions under "Cleaning nozzles").
4. Take off the lance and just spray out of the spray gun. This will indicate if the problem is
with the lance.
1. Make sure there is an o-ring at the end of the metal tip of the high pressure hose. If
no o-ring is present, the connection between the hose and spray gun will leak. O-Ring
Replacement Kit (D) is included with purchase. Additional O-Ring Kits are available
online at www.arblueclean.com or call Customer Service at 1-866-235-5112 to place an
order.
1. All lances are attached and removed from the spray gun in the same manner. Insert
the end of the lance into the spray gun. Press the spray gun and lance together (about
a 1/8 in.) and turn the collar of the gun clockwise. The lance will lock in place. Remove
the lance by reversing this procedure. Press the spray gun and lance together and turn
counter clockwise. The lance will slide out.
Push the whole assembly straight down to loosen the connection, and then follow the
removal process again. You may also spray soapy water or a lubricant in the area where
the lance connects to the spray gun.
1. When the water is connected, the accessories are assembled properly, and the power
is turned on, the power washer may turn on for 1 - 2 seconds to prime the pump. It
automatically shuts off and waits for the spray gun trigger to be pressed. When the
"senses" the moving water and automatically turns the power washer on.
2. Turn the power off, hold in the trigger on the spray gun so that you have a steady stream
of water. While you are holding the trigger open on the spray gun, at the same time, turn
the power on.
2019/1/7 下午2:59