12 Electrical connection

12 Electrical connection
● The enclosed connectors for the power supply and signal line are connected according to the connection diagram.
Depending on the version, one or two connectors are fitted to the housing:
For power supply (labelled with adhesive label showing the type of voltage)
For signal line (not available with design A0)
12.1 Connection/wiring diagram
12.1.1 On/Off actuator with relay (code 00), 24 V DC (code C1)
12.1.1.1 Position of the connectors
X1
X2
Actuator version 2070
12.1.1.2 Electrical connection
3
1
2
Plug assignment X1
Pin
L1 / Uv+, direction of travel CLOSED
1
L1 / Uv+, direction of travel OPEN
2
N / Uv-, neutral conductor
3
PE, protective earth conductor
N / L- signals in the unit are separated.
The potential must be assigned by the user.
When the OPEN and CLOSED switches are operated simultaneously the actuator "CLOSES".
GEMÜ 9468
Risk of electric shock
▶ Risk of injury or death (if operating voltage is higher than safe extra low voltage).
▶ Adjustments are made with the actuator cover removed.
▶ Electric shock can cause severe burns and fatal injury.
Always disconnect the product from power supply!
Therefore, have all work performed only by qualified electricians.
For design AE (additional potential-free limit switches) and design AP (poten-
tiometer output as position feedback), the plug connections must not be confused
with the power supply.
Actuator version 4100, 4200
Description
DANGER
CAUTION
X1
X2
14 / 26
X1
X2
www.gemu-group.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gw-94682070410042006400

Table of Contents