GEM 9468 Operating Instructions Manual page 16

Motorized quarter turn actuator
Table of Contents

Advertisement

12 Electrical connection
12.1.2.2 Electrical connection
1
3
2
Plug assignment X1
Pin
L1 / Uv+, direction of travel CLOSED
1
L1 / Uv+, direction of travel OPEN
2
N / Uv-, neutral conductor
3
PE, protective earth conductor
N / L- signals in the unit are separated.
The potential must be assigned by the user.
When the OPEN and CLOSED switches are operated simultaneously the actuator "CLOSES".
12.1.2.3 Connection diagram
Motor protection switch
recommended
L1/Uv+
External wiring
N/Uv-
PE
Connection assignment X1
12.1.3 On/Off actuator with potentiometer output, with relay (code 0P), 24 V DC (code C1)
12.1.3.1 Position of the connectors
X1
X2
Actuator version 2070
GEMÜ 9468
Description
Direction
switch
CLOSED
OPEN
1
3
2
Actuator version 4100, 4200
6
5
1
4
3 2
Plug assignment X2
Pin
1
Change-over contact limit switch CLOSED
2
Make contact limit switch CLOSED
3
Break contact limit switch CLOSED
4
Break contact limit switch OPEN
5
Make contact limit switch OPEN
6
Change-over contact limit switch OPEN
PE, protective earth conductor
OPEN
Additional
1
4
2
limit switches
5
4
3 2
Connection assignment X2
X1
X2
16 / 26
Description
CLOSED
1
2
4
6
1
X1
www.gemu-group.com
X2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gw-94682070410042006400

Table of Contents