Roof Hatch - Siemens LOGO! 8 Manual

House control with master-slave communication
Hide thumbs Also See for LOGO! 8:
Table of Contents

Advertisement

2 Solution
2.3.2

Roof hatch

Inputs and outputs
Table 2-6
No.
1.
Roof hatch button (make contact)
2.
Roof end switch open (break contact)
3.
Roof end switch close (break contract)
4.
Roof hatch motor up
5.
Roof hatch motor down
Function description
For the roof hatch, a 0.5 seconds pause for the direction change was programmed
for protecting the motor against direct rerouting.
The LOGO! TDE or the LOGO! display can be used to predefine manual or
automatic control of the roof hatch.
In manual mode, the roof hatch can be controlled on the spot with a button. In
addition in manual mode the roof hatch can be controlled remotely over a tablet,
smartphone or PC with the F1 function key over the integrated webserver of
LOGO! 8.
In automatic mode, the roof hatch is controlled with the PT100 (see
depending on the temperature.
The function block for the temperature-dependent control of the roof hatch can be
called up in parameter assignment mode with the respective block name using the
LOGO! display or LOGO! TDE. This enables setting the temperature threshold
values for opening and closing the roof hatch individually.
Table 2-7
No.
1.
Temperature-dependent control of the
roof hatch
Frei verwendbar House Control with Master-Slave - LOGO! Set 9
Entry ID: 64143308,
V2.2,
Hardware
Function
09/2018
LOGO! module
Program inputs/outputs
Master DM16 l1
I9
Master DM16 l2
I10
Master DM16 I3
I11
Master DM16 Q1
Q5
Master DM16 Q2
Q6
Function block
Analog threshold
auto roof (B105)
trigger
Table
2-8)
Block name in the
program