Figure 6 Mounting a Pressure Gauge Set on a 954 SmartServo FlexLine Gauge
Figure 7 Example of Flange Ground
Part No: 4417341 Revision 10

Grounding

WARNING!
For proper grounding of the 954 SmartServo FlexLine, install a copper strip under one of
the flange bolts for each flange. Place shark rings between flange and strip (Figure 7).
NOTE:
Also in case of tanks with cathodic protection, the 954 SmartServo FlexLine must be
grounded to the tank. Cathodic protection can be maintained by isolating the cable
screen/armouring or conduit.
`