Modbus/TCP Kit Installation

ProMix Auto and ProControl Modbus/TCP Variable Map

Run Variables
Address Variable Name
40003
FlowRate
40004
ActualRatio
40005
ActiveRecipe
40006
ActiveFault
40008
PotlifeRemaining
40009
JobComplete
40010
JobTotal0
40012
JobTotal1
40014
JobTotal2
40016
GrandTotal
40018
ControlVer
40020
RobotDigitalIn
40021
RobotDigitalOut
40022
Component
40023
SetupOpen
40026
ccNewRecipe
40027
Opmode
40029
DesFlow
Setup Variables
Address Variable Name
41002
TargetRatio0
41062
TargetRatio60
41063
Tolerance0
41123
Tolerance60
41124
PotlifeTime0
41184
PotlifeTime60
41185
PurgeTime0
41245
PurgeTime60
41246
FillTime0
41306
FillTime60
41307
SolventFillTime
41368
Color0
41428
Color60
41429
Catalyst0
41489
Catalyst60
41490
KFact0
41491
KFact1
41492
KFact2
41493
CalVolume0
12
Size
Min.
Max.
16 bits
0
5000
16 bits
0
9999
16 bits
0
60
32 bits
0
0xFFFF_FFFF 32-bit, 1-bit per Alarm - see detailed table
16 bits
0
9999
16 bits
1
4
32 bits
0
799,999,999
32 bits
0
799,999,999
32 bits
0
799,999,999
32 bits
0
799,999,999
0xFFFF_FFFF Software Version for fluid plate control board
32 bits
0
16 bits
0
0xFFFF
16 bits
0
0xFFFF
16 bits
0
2
16 bits
0
1
16 bits
0
60
16 bits
0
99
16 bits
0
9999
Size
Min.
Max.
16 bits
0
300
16 bits
0
300
16 bits
1
99
16 bits
1
99
16 bits
0
999
16 bits
0
999
16 bits
0
99
16 bits
0
99
16 bits
0
99
16 bits
0
99
16 bits
0
999
16 bits
1
30
16 bits
1
30
16 bits
1
30
16 bits
1
30
16 bits
1
999
16 bits
1
999
16 bits
1
999
16 bits
0
999
Notes
Value is CC/min (0-1200)
10 = 1.0 ratio with decimal
Recipe Number
Time in minutes
JOBCOMPLETE=1, JOBPURGE=2, JOBCC=3,
JOBCCDONE=4
Total for Meter A in CCs
Total for Meter B in CCs
Total for Flow Control Only Inline Meter in CCs
Grand Total in Liters
1-bit for each input, Set/clear for actions - next
detailed table
1-bit for each input, Set/clear for actions - next
detailed table
Active Component (shown on run screen)
1 if in setup screens -> 0 Run Screens
New recipe when RobotDigitalIn recipe bits are
changed
0=MIX 1=PURGE 2=STANDBY 3=COLOR-
CHANGE 4=CC_MIX 5=CC_PURGE 6=METER-
CAL 7=FLOWCAL 8=AUTODUMP
Flow Command Input (Analog)
Notes
300 = 30.0 with decimal
Percentage 1-99%
Minutes
Seconds
Seconds
Seconds
Color Valve for Recipe 0
Color Valve for Recipe 60
Catalyst Valve for Recipe 0
Catalyst Valve for Recipe 60
K-factor for Meter A
K-factor for Meter B
K-factor for Flow Control Only inline meter
Calibration Volume Entered on screen for Meter A
Read
Only
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Read
Only
Y