Scale drawing

1 = display
2 = programming button
3 = thread M18 x 2.5
Operating voltage [V] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.8 ... 30 DC
Current rating [mA] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Voltage drop [V]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 2
Current consumption [mA] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 60
Voltage supply for EPS sensors [V]. . . . . . . . . . . . . . . . . . . . . . . . U
Power-on delay time [s] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5
Response time for the transmission
of the sensor signal [ms] . . . . . . . . . . . . . . . . . . . . . . . OU1 < 50 / OU2 = 0
Housing material
Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 67
Protection class. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . III (SELV; PELV)
Insulation resistance [MΩ] . . . . . . . . . . . . . . . . . . . . . . . . > 100 (500 V DC)
Shock resistance [g] . . . . . . . . . . . . . . . . . . . . 50 (DIN / IEC 68-2-27, 11ms)
Vibration resistance [g] . . . . . . . . . . . . . 20 (DIN / IEC 68-2-6, 10 - 2000 Hz)
Operating temperature [°C] . . . . . . . . . . . . . . . . . . . . . . . . . . . . -25 ... +80
Storage temperature [°C] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40 ... +100
EMC
IEC 1000/4/2 ESD: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IEC 1000/4/3 HF radiated:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 V/m
IEC 1000/4/4 Burst: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 KV
IEC 1000/4/6 HF conducted: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 V
1
34
30
30
24
reverse polarity protection / overload protection
stainless steel (316S12); EPDM/X (Santoprene);
PC (Copolymer); PBTP (Pocan); FPM (Viton)
2
3
Short-circuit protection,
- 1.5V
B
4 / 8 KV
49
page 25