Mitsubishi Electric Hydrobox EHSC Series Installation Manual page 33

Table of Contents

Advertisement

6
Service and Maintenance
Engineers Forms
Commissioning/Field settings record sheet
Main remote controller screen
Setting
Initial settings
Language
°C/°F
Summer time
Temp. display
Time display
Room sensor settings for Zone1
Room sensor settings for Zone2 *1
Room RC zone select *1
Service menu
Thermistor adjustment
Auxiliary settings
Pump speed
Heat source setting
Heat pump flow rate range
Operation
settings
THW1
THW2
THW5B
THW6
THW7
THW8
THW9
THW10
THWB1
Economy settings
for pump.
Electric heater
(Heating)
Electric heater
(DHW) *13
Mixing valve control Running (10 - 240 sec)
Flow sensor *18
Analog output
DHW
Heating/Cooling
Heating opera-
Flow temp.range
tion
*10
*8
Room temp.
control
*15
Heat pump thermo
diff.adjust
Freeze stat function *11
Simultaneous operation (DHW/
Heating)
Cold weather function
Boiler operation
Parameters
EN/FR/DE/SV/ES/IT/DA/NL/FI/NO/PT/BG/PL/CZ/RU/
TR
°C/°F
On/Off
Room/DHW tank/Room&DHW tank /Off
hh:mm/hh:mm AM/AM hh:mm
TH1/Main RC/Room RC1-8/"Time/Zone"
TH1/Main RC/Room RC1-8/"Time/Zone"
Zone1/Zone2
−10°C - +10°C
−10°C - +10°C
−10°C - +10°C
−10°C - +10°C
−10°C - +10°C
−10°C - +10°C
−10°C - +10°C
−10°C - +10°C
−10°C - +10°C
On/Off *6
Delay (3 - 60 min)
Space heating: On (used)/Off (not used)
Electric heater delay timer (5 - 180 min)
Booster heater
DHW: On (used)/Off (not used)
Immersion heater
DHW: On (used)/Off (not used)
Electric heater delay timer (15 - 30 min)
Interval (1 - 30 min)
Minimum(0 - 100L/min)
Maximum(0 - 100L/min)
Interval (1 - 30 min)
Priority(Normal/High)
Pump speed(1 - 5)
Pump speed(1 - 5)
Standard/Heater/Boiler/Hybrid *7
Minimum(0 - 100L/min)
Maximum(0 - 100L/min)
Min.temp.(20 - 45°C)
Max.temp.(35 - 60°C)
Mode(Normal/Fast)
Interval(10 - 60min)
On/Off *6
Lower limit(−9 - −1°C)
Upper limit(+3 - +5°C)
Outdoor ambient temp. (3 - 20°C) / **
On/Off *6
Outdoor ambient temp. (−30 - +10°C) *3
On/Off *6
Outdoor ambient temp. (−30 - −10°C) *3
Hybrid settings
Outdoor ambient temp.
(−30 - +10°C) *3
Priority mode
(Ambient/Cost/CO
2
Outdoor ambient temp. rise (+1 - +5
°C)
Intelligent
Energy
Electricity (0.001 - 999 */kWh)
settings
price
Boiler (0.001 - 999 */kWh)
*9
CO
Electricity
2
emis-
(0.001 - 999 kg -CO 2 /kWh)
sion
Boiler (0.001 - 999 kg -CO
kWh)
Heat
Heat pump capacity
source
(1 - 40 kW)
Boiler efficiency
(25 - 150%)
Booster heater 1 capacity
(0 - 30 kW)
Booster heater 2 capacity
(0 - 30 kW)
Default setting
EN
°C
Off
Off
hh:mm
TH1
TH1
Zone1
0°C
0°C
0°C
0°C
0°C
0°C
0°C
0°C
0°C
On
10 min
On
30 min
On
On
15 min
120 sec
2 min
5 L/min
100 L/min
5 min
Normal
5
5
Standard
5 L/min
100 L/min
30°C
50°C
Normal
10min
On
−5°C
5°C
5°C
Off
−15°C
Off
−15°C
−15°C
Ambient
) *17
+3 °C
0.5 */kWh
0.5 */kWh
0.5 kg -CO
/
2
kWh
/
0.5 kg -CO
/
2
2
kWh
11.2 kW
80%
2 kW
4 kW
(Continued to next page.)
Field set-
Notes
ting
en
32