AARIA ONE INVERTER
EN
USER INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Riello AARIA ONE

  • Page 1 AARIA ONE INVERTER USER INSTRUCTIONS...
  • Page 2 Thank you again, and keep up the good work. RIELLO COMPLIANCE R AARIA ONE INVERTER heat pumps are compliant with the following European Directives: — Low Voltage Directive 2014/35/EU — Electromagnetic Compatibility Directive 2014/30/EU — RoHS Directive 2011/65/EU —...
  • Page 3: Table Of Contents

    AARIA ONE INVERTER TAbLE OF CONTENTS GENERAL INFORMATION ....p. 4 General Notices ......p. 4 Safety precautions .
  • Page 4: General Information

    GENERAl INfORmATION GENERAL INFORMATION This booklet is an integral part of the device, and must General Notices therefore be carefully preserved, and must ALWAYS accom- pany it, even in the event that it is sold to another Owner or User, or is transferred to another system. If it is damaged or lost, another copy can be requested to R Technical When you get the product, check immediately that the con- Support Service in your Area.
  • Page 5: Unit Description

    GENERAl INfORmATION Unit description Identification R AARIA ONE INVERTER is a climate control system without ex- The unit can be identified through the technical data plate: ternal unit suitable for wall installation on any perimeter wall. The aesthetic impact is reduced significantly both on the out-...
  • Page 6: Layout

    GENERAl INfORmATION Layout Control panel Anti-lifting bracket Air outlet deflector 10 Remote control 17 Lower exchanger Front panel Terminal blocks 18 Maximum level float Intake grid 12 Air filter 19 Level float Decorative side panel 13 Room air probe 20 Condensation drain valve External air intake 14 Upper exchanger 21 Four-way valve...
  • Page 7: Controls

    GENERAl INfORmATION Controls 1. Select required ventilation speed: minimum, medium, maximum or automatic 2. Enables Maximum power function Control, adjustment and programming are carried out using the on-board control panel or the infrared remote control. 1. Enables Timer function based on the temperatures detected by the probes present in 2.
  • Page 8: Use

    For the first installation, a CR2025 3.0 V battery is supplied al- Initial settings ready housed in the remote control with the contact being pro- tected by a plastic film. To remove the protective film: Inserting the battery The remote control is powered with a dry lithium battery (CR2025 3.0 V) housed on a support inserted into a slot on the underside.
  • Page 9: Use

    Value is stored with no need to press other buttons. Switch-off • — select another operating mode Cooling mode Alternatively: — press to turn unit off The Cooling mode allows starting and using the system to deliv- er cold and dehumidified air. To activate this function, recom- In this mode the fan starts with a delay with respect to the mended outdoor temperature should be ranging from +10 °C to compressor to prevent a jet of cold air in the environment.
  • Page 10: Ventilation Mode

    — Ventilation Set required ventilation speed as follows: Activation • — press On the unit’s control panel appears. The temperature indicator appears in white. Set required temperature as follows: — act using Value is stored with no need to press other buttons. Switch-off •...
  • Page 11: Motorised Deflector

    perature: + 1 °C + 1 °C Minimum speed Medium speed Sleep function on Maximum speed Sleep function end and unit switch-off Automatic speed: bars light up in sequence Set temperature Maximum power function: all bars flash h Hours passed since function activation —...
  • Page 12: Hotel Function

    — use the control panel cally. — hold down for 10 seconds The symbol d5 flashes. Automatic switch-on The function allows to set the number of hours after which the unit will start automatically. press The range of hours that can be selected is from 1 to 24. The symbol En flashes.
  • Page 13: Temporary Shutdown

    is restored the unit will resume operation with the previously It is forbidden to open the access doors and carry out any active settings. cleaning operation before disconnecting the device from the If the Timer function was active, the time of interruption is not power supply positioning the system main switch to “OFF”.
  • Page 14: Troubleshooting

    RECyClING AND DISPOSAl Troubleshooting fault codes Code Description Remarks Power failure Cooling, Dehumidifying and Heating modes If unit display does not turn on after you press on remote remain active control, and equipment does not turn on, ensure that: Room probe fault The adjustment only —...
  • Page 15 RECyClING AND DISPOSAl regulations.
  • Page 16 RIELLO S.p.A. - 37045 Legnago (VR) tel. +39 0442 630111 - fax +39 0442 630371 www.riello.it As the manufacturer is constantly improving its products, the aesthetic or dimensional features, the technical data, the equipment and accessories indicated could be subject to variations.