Harvest TEC 600BB Installation Manual

Moisture sensor kit for large square balers for new holland bigbaler and case ih lb 4
Hide thumbs Also See for 600BB:

Advertisement

Quick Links

Installation Manual
Model 600BB & 600BBHD
Moisture Sensor Kit for Large Square Balers
For New Holland BigBaler and Case IH LB 4
Forage Harvester
600BB & 600BBHD-20-INST-Imp&Metric
6/20

Advertisement

Table of Contents
loading

Summary of Contents for Harvest TEC 600BB

  • Page 1 Installation Manual Model 600BB & 600BBHD Moisture Sensor Kit for Large Square Balers For New Holland BigBaler and Case IH LB 4 Forage Harvester 600BB & 600BBHD-20-INST-Imp&Metric 6/20...
  • Page 2 European Parliment and the Council of 17 May 2006 and other applicable European Directives including Directive 2004/108/EC on the Electromagnetic compatability. The application of preservatives for hay Harvest Tec system will be turned on after being installed on a farm press has been declard in conformity with the Machinery Directive.
  • Page 3: Table Of Contents

    Installation of iPad Integration Control iPad Integration control Light Signals Bluetooth Receiver Lights Connecting Star Wheels to the DCP – 600BB & 600BBHD Installation of the Star Wheel Moisture Sensors – 600BB Installation of Bale Rate Harness – 600BB Installation of the Star Wheel Moisture Sensors – 600BBHD Installation of Bale Rate Harness –...
  • Page 4: Introduction

    Introduction Thank you for purchasing this 600BB or 600BBHD Moisture Sensor Kit. The Moisture Sensor Kit is designed to operator through the baler’s ISOBUS system and/or an Apple iPad (not included) using the Hay App. The moisture sensor offers these advantages: 1.
  • Page 5: Installation Of The Moisture Sensor Kit

    Installation of the Dual Channel Processor (DCP) 1. Locate the Dual Channel Processor (DCP) 006-6671LS. 2. Lock the baler flywheel brake and lift open the front hood. 3. Locate the four holes by the fly wheel brake (Figure 1). 4. Use four 5/16” x 3” hex bolts with four flat washers (positioning bolt heads on the inside of the baler frame) and secure to the baler with four 1 1/8”...
  • Page 6: Installation And Routing Wire Harnesses And Baler Interface Harness

    Installation and Routing Wire Harnesses and Baler Interface Harness Route harnesses along inside of the baler (Left). Keep harnesses away from moving parts and hydraulic hoses. Secure with existing cable clamps or use cable ties. When all connections are made to the DCP secure wires as shown above to allow for water to be shed away from the DCP.
  • Page 7: Installation Of Ipad Integration Control

    Installation of iPad Integration Control *If not using ISOBUS integration refer to the information below. Locate a safe location in the cab of the tractor to place the iPad Integration Control (030-6672C). Recommended location is securely fastened out of the operators way in a location that is close enough to reach with the iPad cord.
  • Page 8: Connecting Star Wheels To The Dcp - 600Bb & 600Bbhd

    Connecting Star Wheels to the DCP 030-4641 Star Wheel Cover 600BB Locate the moisture harness 006-7303HL. Remove the pan head screws on each star wheel and remove the star wheel cover. Loosen the black grommet. Insert the eye loop of the wire into the star wheel block through the Grommet grommet and install on the end of the swivel.
  • Page 9: Installation Of The Star Wheel Moisture Sensors - 600Bb

    Installation of Star Wheel Moisture Sensors – 600BB Figure 1 1. Locate the two star wheel moisture sensors (030-4641) and twine diverters (001-4644 & 001-4645). 2. Directly behind the knotters, locate the four predrilled holes per side shown at the arrows. This location is also beneath the lift points on Figure 2 top of the baler (Figure 1).
  • Page 10: Installation Of The Star Wheel Moisture Sensors - 600Bbhd

    Installation of Star Wheel Moisture Sensors – 600BBHD 001-4644BBHD 1. Locate the two star wheel moisture sensors (030-4641U) and star wheel reinforcement brackets (001-4644BBHD) show on the right and parts bag A. 2. The two pre-drilled mounting holes for the star wheels are located past the knotters on the side of the top support bar running the length of the bale chute (Figure 1).
  • Page 11: Installation Of Bale Rate Harness - 600Bbhd

    Processor (DCP). The Dual Channel Processor is located next to the flywheel brake. Installation of End of Bale Sensor – 600BB The end of bale sensor determines the position of the needles on the baler. When the needles cycle the sensor communicates this information to the Dual Channel Processor.
  • Page 12: Wiring Diagram

    F. Connect the iPad Integration Control (030-6672C) to the Communication Harness (006-6650TM). G. Note: The Optional Port and the Data Transfer Port are not used in this application. Moisture/Bale Rate Harness Proximity Sensor Star Wheel Assembly 006-7303HL (600BB) 006-7303S 006-4641 (600BB) Dual Channel Processor (DCP)
  • Page 13: Pin Outs

    Pin Outs Power/Comm Harness 006-6650TM(E) at Hitch Pin 1 Red +12V Power to TSD Pin 2 Red +12V Power to DCP Pin 3 Orange Keyed Power Pin 4 Gray Shield Pin 5 Green HT Can Low Pin 6 Yellow HT Can Hi Pin 7 Orange Can1 Hi Pin 8 Black...
  • Page 14 Pin Outs (continued) 006-6650VA to 006-6650LS(E) Pin 1 Red Can Power Pin 2 Black Can Ground Pin 3 Yellow HT Can Hi Pin 4 Gray Shield Pin 5 Green HT Can Low Pin 6 N/A Pin 7 N/A 006-6650VA Harness to Baler Plug Pin A N/A Pin B Red TBC Power...
  • Page 15: Troubleshooting

    5. Short in wire between star 5. Replace wire. wheels and DCP. 6. Check hay with hand tester 6. Contact Harvest Tec if conditions to verify. persist. Moisture readings erratic. 1. Test bales with hand tester to verify that DCP has more variation than hand tester.
  • Page 16: Parts Breakdown

    Parts Breakdown Controls and Harnesses Ref Description Part Number DCP Baler ISO/VT Harness 006-6650VA EOB Extension for CNH BB Series 006-7400BBEXT Key Switch Wire 006-5650K End of Bale Sensor 600 Series 006-7400 End of Bale Sensor Bracket 001-4648 Terminating Connector 600 Series w/green cap 006-5650Z DCP Shield/Cover 001-5650X DCP Main Control LS 600 AUTO...
  • Page 17: Star Wheel Sensors

    600BB Star Wheels Description Part# Star wheel sensor 030-4641C Snap ring (per side) 006-4641K Washer (per side) w/006-4641K Dust seal (per side) w/006-4641K Star wheel block 006-4641A Wiring grommet 008-0821A Plug fitting 003-F38 Swivel insert w/ Ref # 1 Electronic swivel...
  • Page 18: Optional Ipad Display Kit

    Optional iPad Display Kit (030-4670DK) Description Part # Ref Description Part # Suction cup mount 001-2012SCM iPad Mini Charger 12V 001-2012P Ram mount 001-2012H iPad Mini 4 case 001-2012C4 ® iPad Mini spring load 001-2012SLC iPad Mini 4 006-4670IP cradle (Mini 4) 16 gauge power wire 006-4723P 4 amp fuse...
  • Page 19: Warranty

    Harvest Tec, Inc. within 30 days of the failure. If it is determined that a non-Harvest Tec branded hay preservative has been used inside the Harvest Tec applicator system where the failure occurred, then Harvest Tec reserves the right to deny the warranty request at their discretion.
  • Page 20 HARVEST TEC, INC. P.O. BOX 63 2821 HARVEY STREET HUDSON, WI 54016 PHONE: 715-386-9100 1-800-635-7468 FAX: 715-381-1792 Email: info@harvesttec.com...