Parameter Adjustment Mode - Ransburg 80100 Series Service Manual

High voltage controller, hv1 - automatic guns
Table of Contents

Advertisement

9060 High Voltage Controller - Operation
To navigate through the digital indexes, use the
- and + buttons. Both buttons change the index
by 1 for each press and will automatically wrap
back around when the either end of the list is
reached.
Gun Type/Firmware Version
Mode
This sub mode will display the gun type display
value on the kV display and the firmware
version number on the µA display as shown
during startup in Figure 18 during startup. As
this is a sub mode of the remote I/O monitoring
diagnostic mode, it will not have a limited
display duration and will remain on the screen
until either a different sub mode is entered or
the diagnostic mode is exited.
N O T E
The Parameter Adjustment Mode is
available for ES (Esta-Quick, Evolver SE)
and Ab (Aerobell 168) automatic applica-
tors.
PARAMETER
ADJUSTMENT MODE
Certain parameters within the 9060 High
Voltage Controller can be adjusted depending
on the applicator being used. To enter the
parameter adjustment mode, press the preset 1
and preset 3 keys at the same time. This will
bring up the parameter adjustment mode as
shown in Figure 29. A summary of key opera-
tions for parameter adjustment mode is shown
in Figure 30.
In parameter adjustment mode, the kV display
will show the 2-character code for the parame-
ter and the µA display will show the currently
set value for the parameter. Each parameter
has its own specific range limits, increment
values, and indicators (if applicable).
adjustable parameter table lists the currently
available parameters by character code along
with their attributes.
35
Figure 29: Parameter Adjustment Mode (Overload)
Adjustable Parameters
Code Parameter Min/Max Inc.
Current
OL
Overload
Startup
Hd
Holdtime
Sample
SA
Time
SE
Sensitivity
Navigating Parameters
When a parameter is currently not selected, the
- and + buttons are used to navigate from one
parameters to another.
pressed the previous parameter will be display.
If the + button is pressed the next parameter
will be displayed. The parameter adjustment
menu has a wrap around indexing, so it if the
end of the parameter list is reached in one
direction it will automatically moved to the other
end.
Selecting/Deselect Parameters
The preset 2 button is used to select/deselect
the currently displayed parameter to allow it to
be modified.
parameter, the value on the µA display will
begin flashing.
has been selected and can be edited. If the
The
preset 2 button is pressed when a parameter is
already selected, it will be deselected and all
modifications will be lost.
value will stop flashing indicating it has been
deselected.
Indicators
Decimal marker
on code means
20/190
5
overload jumper is
installed
2/15
0.5
seconds
sec.
Available only
2-50
1
on 51X Units
Available only
1.0-12.0
1
on 51X Units
If the - button is
When pressed to select the
This indicates the parameter
The parameter's
N/A
CP-13-05.3