Ransburg 80100 Series Service Manual page 21

High voltage controller, hv1 - automatic guns
Table of Contents

Advertisement

High Voltage On (Relay Output
)
Dry Contact
The "HV on" signal (TB2-4) is available in both
LOCAL and REMOTE modes.
being a relay controlled signal, can be config-
ured as either an AC or DC signal using the
Relay Common Input as the signal source.
For information regarding the relay contact
voltage ratings, please refer to the "Relay
Output Contacts" portion of the "Installation"
section of the manual. This relay signal is
activated when the High Voltage cascade is
turned on.
Fault (Relay Output
The "Fault" signal (TB2-2) is available in both
LOCAL and REMOTE modes.
being a relay controlled signal, can be config-
ured as either an AC or DC signal using the
Relay Common Input as the signal source.
For information regarding the relay contact
voltage ratings, please refer to the "Relay
Output Contacts" portion of the "Installation"
section of the manual. This relay signal is
activated when a Fault Condition or Overload
Condition has faulted the 9060 Controller.
Relay Common Input
The relay common input (TB2-3) is a shared
connection between the Fault and HV on relay
outputs.
This is the source of their output
voltage. It can be wired to either an AC or DC
signal. It is most commonly connected to the
24 VDC power provided at (TB2-1).
allows the relays to output 24 VDC signals
without the use of any outside power sources.
CP-13-05.3
9060 High Voltage Controller - Introduction
,
This signal,
)
, Dry Contact
This signal,
This
N O T E S
16