Ensure that the coat is not damaged!
Any damage may cause failure of the external protective coating and corrosion.
Unless otherwise contractually agreed, the interior preservation is guaranteed for 24 months,
and the exterior preservation for 36 months, provided that storage is in dry, frostfree sheds.
The guarantee period starts on the date of delivery or that of the notice that the item is ready
for shipment.
For longer periods of storage (> 24 months) we advise regular checking and, if necessary, renewal of the
interior and exterior preservation (see items 7.3.1 and 7.3.2).
The output shaft must then be rotated at least one turn to change the position of the rolling element in the
bearings. The input shaft must not be in the same position as before rotation.
This procedure must be repeated and documented every 6 months until start­up.
4.4.1

Interior preservation with preservative agent

Table 4:
Durability period and measures for interior preservation when using mineral oil or PAO­based
synthetic oil
Duration of protection
Up to 6 months
up to 24 months
For storage periods longer than 24 months, renew the preservative agent.
For storage periods longer than 36 months, Siemens should be consulted before.
Table 5:
Durability period and measures for interior preservation when using PG­based synthetic oil
Duration of protection
Up to 6 months
up to 36 months
For storage periods longer than 36 months, Siemens should be consulted before.
1)
Resistant to tropical conditions and sea water; maximum ambient temperature 50 °C
Preservative agent
Castrol Alpha SP 220 S
Preservative agent
Special anti-corrosion oil
1)
TRIBOL 1390
BA 5060 EN 04/2011
17 / 62
Special measures
None
- Close all holes in the gear unit.
- Replace wet-air filter with screw plug.
(Prior to start-up replace screw plug
with wet-air filter.)
Special measures
None
- Close all holes in the gear unit.
- Replace wet-air filter with screw plug.
(Prior to start-up replace screw plug
with wet-air filter.)