Energy saving mode temperature differential: (-30.0 to 30.0°C; -54 to 54°F) sets the increasing
HES
value of the set point during the Energy Saving cycle.
Energy saving controls the lights (lights OFF when energy saving is active): (n; Y) lights off
LdE
when energy saving mode is active
Period to switch from normal mode to energy saving mode: (0.0 to 24h00min, res. 10 min) if
StE
the door stay closed for StE time, the energy saving mode will be activated. NOTE: this will require
a door switch to work.
Period to switch from energy saving mode to normal mode: (0.0 to 24h00min, res. 10 min)
EtS
maximum time for energy saving mode. NOTE: this will require a door switch to work.
Door open time to switch from EtS to StE: (0 to 999 sec) the energy saving mode will be
dS
immediately deactivated as soon as the door stays open more than the dS time. NOTE: this will
require a door switch to work.
Number of motion detections before disabling energy saving mode (valid if ixF=EMt): (0 to
nES
255) number of motion sensor detections before disabling the energy saving mode.

5.1.12 Counters, read only values - Cnt

n1H
Number of activations for relay output oA1 (thousands of)
n1L
Number of activations for relay output oA1 (units of)
n2H
Number of activations for relay output oA2 (thousands of)
n2L
Number of activations for relay output oA2 (units of)
n5H
Number of total activation of digital input 1 (thousand of)
n5L
Number of total activation of digital input 1 (units of)
n6H
Number of total activation of digital input 2 (thousand of)
n6L
Number of total activation of digital input 2 (units of)
F1H
Number of working hours for relay output oA1 (thousands of)
F1L
Number of working hours for relay output oA1 (units of)
F2H
Number of working hours for relay output oA2 (thousands of)
F2L
Number of working hours for relay output oA2 (units of)

5.1.13 Real Time Clock configuration parameters - rtC

Hur
Hours: 0 to 23 hours
Min
Minutes: 0 to 59 minutes
dAY
Day of the week: Sun to Sat
dYM
Day of the month: 1 to 31
Mon
Month: 1 to 12
YAr
Year: 00 to 99
Hd1
First day of weekend: (Sun to SAt; nu) setting for the first day of the weekend.
Hd2
Second day of weekend: (Sun to SAt; nu) setting for the second day of the weekend.
Energy saving cycle start time on working days: (00h00min to 23h50min) during the Energy
iLE
Saving cycle, the set point is increased by the value in HES so that the operation set point is
SET+HES.
Energy saving cycle duration on working days: (00h00min to 24h00min) sets the duration of
dLE
the Energy Saving cycle on working days.
iSE
Energy saving cycle start time on weekends: 00h00min to 23h50min
dSE
Energy saving cycle duration on weekends: 00h00min to 24h00min
Daily defrost enabled: (n; Y) to enable the Ld1 to Ld6 defrost operations for any day of the
week.
dd1 = Sunday defrost
dd2 = Monday defrost
dd3 = Tuesday defrost
ddx
dd4 = Wednesday defrost
dd5 = Thursday defrost
dd6 = Friday defrost
dd7 = Sunday defrost
Defrost start time: (00h00min to 23h50min) these parameters set the beginning of the
Ldx
programmable defrost cycles during any ddx day. Example: when Ld2=12.4, the second defrost
starts at 12:40 am during working days.