• Always transport the dehumidifier in an upright position. Before using
the dehumidifier for the first time, leave it standing in an upright position
for 24 hours. Always stand the dehumidifier in an upright position imme-
diately after transporting the appliance, and wait for at least 60 minutes
before switching it back on. The water tank must be emptied every time
before transport.
• The dehumidifier must always be operated according to this instruction
manual. Non-observance of these instructions can lead to injuries, a fire,
electric shock or faults in the appliance.
• The dehumidifier is designed for private use indoors and is not intended
for commercial use.
• Do not use the dehumidifier if it is faulty or could show signs of damage,
or if it is not functioning correctly. Disconnect the plug from the power
socket.
• Repairs to electrical appliances must only be carried out by a qualified
electrical technician. If improper repairs are carried out, the warranty
lapses and all liability is refused.
• The appliance shall be installed in accordance with national wiring regu-
lations.
• If the unit is not used for a longer period of time, switch it off and unplug
it, empty the water tank, pack it after 48 hours while the inside compo-
nents are dry, keep it then in a dry and ventilated place. When storing
the unit, please make sure it stands in an upright position. Never put it
upside down.
• Prior to any maintenance, cleaning and after each use, switch off the ap-
pliance and unplug the mains cable from the socket.

Setting up / operation

1. Place Albert on a flat surface in the desired area. Plug the power cable
(16) into an electric socket.
2. Press the on/off switch (3) to turn on the dehumidifier.
3. You can select the speed of the fan in the dehumidifier by pushing the
speed level selector (5). There are 3 speed levels. If the speed is higher,
the dehumidifying performance also increases.
4. With the hygrostat (4) the desired humidity level can be set. Press on
the knob hygrostat (4) and change to desired humidity level with the
rotary control (10). Humidity levels between 30 and 80 % or continuous
running (CO in display) can be selected. A humidity level not higher than
60 % is suggested in general. If the dehumidifier reached the selected
humidity it will turn off and after that check the humidity level in con-
stant intervals by turning on the fan for a short time.
5. With the timer you can selecte precisely when Albert should be run-
ning. The timer can be activated by pressing the knob timer on/off (6)
and the LED will be lit. If you press the knob again the timer will not be
active and the LED will be off. To set the timer follow these instructions:
6. Set the time: Press set (7) for 5 seconds and the symbol for hour is
shown blinking in the display, in addition the hours are blinking. Now
you can choose the correct hour with the rotary control (10). If the hours
are correct, press set (7) again and the minutes can be adjusted the
same way. To finish press set (7) again.