The second column of the System Status Table indicates the state of each of the STG system elements.
A green state is good and a red state indicates an issue. A normal state for the Sip Input element is
Listening, and a normal state for a TAP output is
Logged
IN. Problem states can include
USB
Disconnected, and
Trying to
Login.
The third column of the System Status Table is used to indicate how many messages are in each output
queue. A normal state is indicated by "0 Messages in Queue." The STG maintains a message queue for
any paging system that is detected and logged into at startup, as well as any paging system that is
detected and logged into after a USB adapter connection is dynamically detected. If a paging system is
disconnected and reconnected, the queued messages will be delivered to that paging system.

View Log

The Click Here to View Log link under the Status Table allows you to view the communications logs for
the STG (See Examining STG Log Data section below).

Update STG Software

The Update STG Software button allows the STG to detect and apply any software changes. Upon click
of the Update Software button,
the system attempts to retrieve an update script from the WaveWare web
site. In combination with update script retrieval, the system restarts and applies the update script. This
feature requires the STG to have internet access. Note that the update process can take up to 25
minutes and the STG should not be interrupted as it goes through up to two restart cycles. You
can observe the status of the upgrade process by connecting a monitor to the STG HDMI port.
Once fully updated, the HDMI output will display the STG configuration page in a web browser. If
the update process fails, please take a photograph of the HDMI output for troubleshooting
purposes.

Clear Message Queue

The Clear Message Queue button allows the outgoing message queue(s) to be cleared. The purpose of
this feature is primarily to reduce the amount of radio paging output when paging system overrun
conditions occur. The only practical applications of the Clear Message Queue feature are when load
testing the STG, when a paging system is not connected to a serial port during periods of activity, when
exercising the system during installation, and when paging system communication failures occur,
causing the output queue to build up.

Reset STG to Default Settings

The Reset STG to Default Settings button allows the STG default settings to be restored. In addition the
system log files will be cleared.

Brekeke SIP Server Dialplan Configuration

The simplest Dialplan Rule to use with the Brekeke SIP Server is:

Matching Pattern:

$request = ^INVITE
$registered = ^false
To = sip:(.+)@