Page 1
Installation Reference Manual 912L LA Vehicular swing gate actuator TITAN12L/12L1 912L actuator IMPORTANT! These instructions apply only to the 912L actuator. Control box installation/operation is described in a separate control box manual. www.ApolloGateOpeners.com | (800) 878-7829 | Sales@ApolloGateOpeners.com...
INSTALLATION REFERENCE MANUAL SECTION 1: TITAN 912L ACTUATOR OVERVIEW Congratulations on selecting a Nice TITAN 912L actuator. With proper selection, system design, installation and maintenance this operator should provide years of reliable operation. This manual covers ONLY the instal- lation of the actuator.
• The gate for which the gate operator is intended to be used should itself be installed correctly so that it is level and plumb and the gate opens easily and evenly. • Note that Nice swing gate systems are not intended for installation on an incline. WARNING!
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL SECTION 4: ACTUATOR - MECHANICAL INSTALLATION INSTALL PIVOT ARM TO GATE: PULL-TO-OPEN 1. Securely mount the pivot arm to the hinge post (IMAGE 1A-1). 2. If necessary, cut pivot arm for correct placement of the actuator mounting hole. Measurements are taken from the center of pivot of the gate hinge (IMAGE 1A-1).
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL INSTALL PIVOT ARM TO GATE: PUSH-TO-OPEN 1. Securely mount the pivot arm to the hinge post (IMAGE 1B-1). 2. If necessary, cut pivot arm for correct placement of the actuator mounting hole. Measurements are taken from the center of pivot of the gate hinge (IMAGE 1B-1).
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL MOUNT ACTUATOR TO PIVOT ARM 1. Mount actuator to pivot arm as shown in IMAGE 2-1 using 1/2” bolt and lock nut. Tighten until secure. 1/2”x 3.5” BOLT PIVOT ARM ACTUATOR 1/2”LOCK NUT IMAGE 2-1: INSTALLING ACTUATOR TO PIVOT ARM 2.
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL AFFIX GATE BRACKET TO ACTUATOR ARM If the gate bracket is not already installed on the actuator arm, mount gate bracket to actuator arm with the pivot bolt, nut, and washers per images below.
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL POSITION GATE BRACKET ON GATE 1. Place gate in: a) CLOSED position for PUSH-TO-OPEN configurations ( IMAGE 4-1). b) OPEN position for PULL-TO-OPEN configuration (IMAGE 4-2). 2. With actuator arm fully retracted, rotate entire actuator on the pivot arm around until the gate bracket attached to the actuator is positioned on a supporting structure of gate.
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL AFFIX GATE BRACKET TO GATE 1. Weld the gate bracket to the gate supporting structure (IMAGE 5-1) or use supplied 3/8” bolts and nuts from kit (IMAGE 5-2). CAUTION! NEVER WELD PARTS TO THE GATE OR POSTS WHEN THE CONTROL BOARD IS...
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL OPEN MECHANICAL RELEASE 1. Lift up the rubber key cap (#1, IMAGE 6-1A). 2. Insert key and turn 90° clockwise (#2, IMAGE 6-1B). 3. Lift up the mechanical release (#3, IMAGE 6-1C). 4. After mechanical release is opened, the actuator arm should now be freely extended and retracted manually.
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL MANUALLY SET GATE OPEN/CLOSE LIMITS MANUALLY SET GATE OPEN/CLOSE LIMITS To mechanically “teach” the actuator the rough open and close limits, ensure the machanical release is still open on the actuator, then move the gate manually as follows: IMPORTANT! If done carefully, manually setting the gate limits may not require further adjustment.
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL RUN ACTUATOR CABLE(S) TO CONTROL BOX RUN ACTUATOR CABLE(S) TO CONTROL BOX Run the cable of the actuator closest to the control box through a hole (with rubber grommet) drilled in the bottom on the control box. If necessary, entry may be made elsewhere on the control box.
TITAN 912L Actuator Input AutoClose Receiver Exit INSTALLATION REFERENCE MANUAL Options SECTION 5: 912L ACTUATOR WIRING Open Open 936 CONTROL BOARD WIRING: PULL-TO-OPEN Close Fire Stop Connect harness wires to MOTOR 1 for your chosen configuration per Instruction 9A, 9B, 9C, or 9D.
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL 1050 CONTROL BOARD WIRING: PULL-TO-OPEN 1050 CONTROL BOARD WIRING: PULL-TO-OPEN MOTOR 1 MOTOR 1 IMAGE 9C-1: 1050 BOARD - PULL-TO-OPEN - SINGLE GATE MOTOR 1 MOTOR 2 2nd ACTUATOR WITH LONGER HARNESS TO MOTOR 2...
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL 1050 CONTROL BOARD WIRING: PUSH-TO-OPEN 1050 CONTROL BOARD WIRING: PUSH-TO-OPEN MOTOR 1 MOTOR 1 IMAGE 9D-1: 1050 BOARD - PUSH-TO-OPEN - SINGLE GATE MOTOR 1 MOTOR 2 2nd ACTUATOR WITH LONGER HARNESS TO MOTOR 2...
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL SECTION 6: SETTING ACTUATOR FINE LIMITS After installation of the control box (per separate installation instructions), the first operation to perform after the board has scanned for monitored safety devices is to ensure the open and close limits are acceptable.
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL SETTING ACTUATOR FINE LIMITS: PUSH-TO-OPEN 1. Open the actuator mechanical release, remove two Torx 25 screws, and lift off cover. 2. Remove plastic cap covering the two adjustment wheels (IMAGE 10-1). 3. Press the CLOSE button on the control board. The gate should close until it hits the CLOSE limit switch (LED = RED).
TITAN 912L Actuator INSTALLATION REFERENCE MANUAL SECTION 8: PART DRAWINGS Cover, Upper, Motor Motor, Electric, 12V, Complete Bracket, Pivot, Weld-On Limit Switch Lever Lock Cylinder Kit, Key and Latch Bracket, Pivot, Bolt-On Motor, Electric, 12V Bracket, Gate Attach Cover, Bottom,...
Page 22
This warranty will be interpreted, construed, and enforced in all respects in the name plate of a manufacturer other than HySecurity or Nice and they are not a accordance with the laws of the State of Washington, without reference to its part of the base model.