Commissioning; Before Commissioning; Commissioning Procedure - Danfoss VLT Safety Option MCB 152 Installation Manual

Hide thumbs Also See for VLT Safety Option MCB 152:
Table of Contents

Advertisement

Installation Guide | VLT®Safety Option MCB 152

5 Commissioning

5.1 Before Commissioning

When commissioing/recommissioning:
Secure the site in accordance with regulations (barrier, warnings, signs, and more). Only qualified personnel is allowed to
commission/recommission the system.
Refer to the guidelines, information, and specifications stated in the operating guide of the relevant programmable control system.
Make sure that no personal injury and/or material damage can occur, even if the plant/machine moves unintentionally.
ELECTROSTATIC DISCHARGE
Electrostatic discharge can damage components.
Ensure discharge before touching the safety option, for example by touching a grounded, conductive surface or by wearing
-
a grounded armband.
RISK OF ELECTROCUTION
Wiring the electrical connections on the drive while voltage is applied can lead to death or serious injury.
Switch off power.
-
Make sure that the control cabinet is provided with an access lock or warning signs.
-
DO NOT switch on voltage until the system is commissioned.
-
Refer to the VLT® AutomationDrive FC 301/FC 302 Operating Guide or the VLT® Decentral Drive FCD 302 Operating Guide for further
information on the drive. Refer to the VLT® Motion Control Tool MCT 10 Operating Guide for further information on the Safe Plug-in.

5.2 Commissioning Procedure

Prerequisites:
The following components are required to perform the necessary steps for commissioning the safety option:
Installation of MCT 10 Set-up Software version 4.40 or later.
A connection between the PC and the control card of the drive.
If RS485 is used, set the protocol for serial communication to [0] FC-MC in parameter 8-30 Protocol (only accessible through the
LCP).
Danfoss A/S © 2020.02
C A U T I O N
W A R N I N G
N O T I C E
Commissioning
AN327351953089en-000101 / 130R0578| 27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt decentral drive fcd 302Vlt automationdrive fc 302