Idex Knight On-Premise Pro Instruction Manual page 9

Table of Contents

Advertisement

Selecting delay time units:
Pump delay times can be set in one second increments
for 0 - 255 seconds, or one minute increments for 0 - 99
minutes. Determine the longest delay time required for
the system, and select the appropriate delay time units.
(1) Enter the access code if you do not already have
access to the system.
(2) Select pump 3, and formula A.
(3) Use  to choose 001 (seconds) or 060 (minutes)
on the 3-digit display, then ENTER.
SECONDS
001
MINUTES
(4) The display will flash briefly, indicating that the
delay unit selection was accepted.
Programming pump delay times:
(1) Enter the access code if you do not already have
access to the system.
(2) Ensure that the delay time LED is flashing. If the
pump time LED is flashing, press MODE to choose
delay time.
(3) The 3-digit display will show
―seconds‖ or will show -
―minutes‖.
(4) Choose the desired pump and formula using their
respective SELECT buttons.
(5) Use / to input a new delay time or to change an
existing delay time (if a delay time is already
programmed, it will show up in the 3-digit display
when you press /).You can hold down on the
arrow button if you wish to rapidly advance the
numbers.
(6) Press ENTER and the display will flash briefly,
indicating that the delay time was accepted.
0901133 Rev: A (11/13)
060
if delay units are in
if delay units are in
NOTE: During delay time countdown -
indicating a countdown in one minute increments. If
programmed to delay in one second increments, the
display will count down from the delay time to zero.
COUNTDOWN
SECONDS
000
MINUTES
Programming flush times:
See Flush Manifold instruction manual for installing
Flush Manifold with dispenser.
(1) Enter the access code if you do not already have
access to the system.
(2) Dispense a small amount of colored chemical into
manifold.
(3) Choose pump F and the desired formula using the
pump and formula SELECT buttons.
(4) Ensure that the pump time LED is flashing. If the
delay time LED is flashing, press MODE to choose
pump time.
(5) Press CALIBRATE. The flush solenoid will activate
and the 3-digit display will begin counting.
(6) Once all colored product has been cleared from
the line to the washer, press CALIBRATE again to
stop the water flush. The display will stop counting
and the 3-digit display will show the time it took to
flush line.
(7) Press ENTER and the display will flash briefly,
indicating that the flush time was accepted.
(8) Repeat this procedure for each formula used, or
simply note the flush time from step 6, and
manually enter this time for pump F on each
formula used.
will display
-00
Page 9 of 20