System reset timer:
The system can be programmed to delay the reset for
up to 75 minutes after the load count pump starts. This
is useful where the system may receive extra signals in
the final rinse or extract cycles (common on smaller
European machines).
To set the timer:
(1) Enter the access code if you do not already have
access to the system.
(2) Select pump 8, and formula A.
(3) Ensure that the pump time LED is flashing. If the
delay time LED is flashing, press MODE to choose
pump time.
(4) Use / to set the desired reset time. You can hold
down on the arrow button if you wish to rapidly
advance the numbers.
(5) Press ENTER and the display will flash briefly,
indicating that the reset time was accepted.
0901133 Rev: A (11/13)
Formula enable/disable:
This feature allows you to choose only those formula
numbers that you want visible to the operator for
selecting the chemical formula from the On-Premise Pro
remote control. This makes the remote control more
user-friendly to the operators, and eliminates the chance
of missed chemical injections due to inadvertently
choosing an unused formula.
By default (for a new dispenser or after clearing
memory) the formula enable feature is reset and all
formula numbers are visible. If you wish to ―turn
off‖ (disable) certain formulas, they will not be visible to
operators but will appear when the control is accessed
for programming.
To enable or disable a formula:
(1) Enter the access code if you do not already have
access to the system.
(2) Select pump F.
(3) Ensure that the delay time LED is flashing. If the
pump time LED is flashing, press MODE to choose
delay time.
(4) Select the formula number that you wish to enable
or disable.
(5) Use  to choose 000 (enable) or 001 (disable) on
the 3-digit display, then ENTER.
(6) The display will flash briefly, indicating that the
enable/disable status was accepted.
(7) Repeat steps 3 – 5 for all formulas that you wish to
disable.
NOTE: If you inadvertently disable all formulas, the
control will automatically enable formula 1 so there will
at least be one available formula.